Function description
4.9

Wave

With the wave function, a safety laser scanner that is to be configured in a network can be
identified more easily from its position.
When starting the automatic search for a safety laser scanner in a network the wave button
can be selected.
The device found registers with the flashing message
4.10

Muting

The muting function can be used to suspend the safety laser scanner during operation,
subject to special operating conditions.
}
Example of a special operating condition:
Material is transported into the protective zone on a conveyor and the safety laser scan-
ner is overridden for the time it takes the material to pass through.
Muting proves to be particularly suitable when, under certain operating conditions, an object
is permitted to pass through the danger zone but a person is not.
Identification of the conveyed material (pallets, vehicles...) must be guaranteed with all
}
Material dimensions and
}
Conveyor speeds
that are intended to arise during operation.
Operating Manual PSEN sc M 3/5 series
1005055-EN-02
PSEN sc 3/5 M b/e
PSENscan Configurator
Evaluation device
PSEN sc 3/5 S
in the display.