Implemented protocols in UNIGATE® CX C4Map
7.2
Implemented Protocols - DeviceNet
In addition to the "Delta exchange" protocol, the universal script also contains other protocols.
However, these cannot be used for communication with the "CANopen (Mapping)" protocol.
7.2.1
Protocol Delta exchange
The Delta exchange protocol can only be used from version 1.9.0 of the universal script Deutsch-
mann.
With this protocol, data can be specifically copied to an area on the fieldbus output side, i.e. from
®
the UNIGATE
to the PLC.
To do this, two control parameters, the address offset and the number of bytes, are required at
the start of the transfer before the actual user data then follows. First comes the address offset
(Word), then the number of bytes (Word), then the user data as a byte array.
The two parameters (address offset and number of bytes) must be sent with every data transfer.
1st byte address offset high
2nd byte address offset low
3rd byte number of bytes high
4th byte number of bates low
5th byte user data 1st byte
6th byte "2nd byte
7. "...
Example:
1st byte 0x00
2nd byte 0x02
3rd byte 0x00
4th byte 0x05
5th byte 0x01
6th byte 0x02
7th byte 0x03
8th byte 0x04
9th byte 0x05
In the fieldbus output data (e.g. PROFIBUS), the data is sent to the PLC as follows
sent: 0x00 0x00 0x01 0x02 0x03 0x04 0x05 0x00 ...
7.3
The trigger byte
If data is transferred cyclically via DeviceNet (which is usually not the case), the gateway must
detect when the user wishes to send new data via the serial interface. For this reason, the user
can set control of transmission via a trigger byte (data exchange
the gateway always sends (and only then) when the trigger byte is changed.
If the Trigger-Byte mode is activated, the gateway increments the trigger byte each time a tele-
gram has been received.
The first byte in the DeviceNet input/output data buffer is used as the trigger byte if this mode is
activated.
22
Fieldbus-Gateway UNIGATE
Deutschmann Automation GmbH & Co. KG
→
On Trigger). In this mode,
®
CX C4Map - DeviceNet V. 1.0
25.9.20