Sign In
Upload
Manuals
Brands
DEUTSCHMANN AUTOMATION Manuals
Gateway
UNIGATE CL-Fast Ethernet
DEUTSCHMANN AUTOMATION UNIGATE CL-Fast Ethernet Manuals
Manuals and User Guides for DEUTSCHMANN AUTOMATION UNIGATE CL-Fast Ethernet. We have
1
DEUTSCHMANN AUTOMATION UNIGATE CL-Fast Ethernet manual available for free PDF download: Instruction Manual
DEUTSCHMANN AUTOMATION UNIGATE CL-Fast Ethernet Instruction Manual (50 pages)
Universal Fieldbus-Gateway
Brand:
DEUTSCHMANN AUTOMATION
| Category:
Gateway
| Size: 0 MB
Table of Contents
Table of Contents
3
1 Information on CE Marking of the Module
8
EU Directive EMC
8
Scope of Application
8
Note Installation Guidelines
8
Installation of the Unit
8
Working on Switch Cabinets
8
2 Information for the Machine Manufacturers
9
Introduction
9
EU Machinery Directive
9
3 Introduction
10
UNIGATE ® CL Software Flow-Chart
11
UNIGATE ® Application Diagram
12
4 Operation Modes of the Gateway
13
Configuration Mode (Config Mode)
13
Test Mode
13
Data Exchange Mode
13
5 RS-Interface
14
RS-Interfaces at the UNIGATE ® CL
14
Buffer Sizes at the UNIGATE ® CL
14
Framing Check
14
6 SSI-Interface
15
Initiation of the SSI-Interface
15
Hardware-Wiring
16
7 The Debug-Interface
17
Overview of the Debug-Interface
17
Starting in the Debug-Mode
17
Communication Parameter for the Debug-Interface
17
Possibilities with the Debug-Interface
17
Commands of the Debug-Interface
17
8 Mode of Operation of the System
18
General Explanation
18
Interfaces
18
Data Exchange
18
Possible Data Lengths
18
Startup Phase
18
9 Generating a Script
19
What Is a Script
19
Memory Efficiency of the Programs
19
What Can You Do with a Script Device
19
Independence of Buses
19
Further Settings at the Gateway
19
The Use of the Protocol Developer
20
Accuracies of the Baud Rates
20
Script Processing Times
21
10 Implemented Protocols in UNIGATE
22
Protokoll: Transparent
22
Data Structure
22
Protocol: Universal 232
22
Fieldbus Parameters
22
CL with Universal Script
22
RS232 Parameter Table
23
End Character (232 End Character)
23
Length 232 (232 Length)
23
Start Character (232 Start Character)
23
Communication Sequence
23
Protocol: 3964(R)
23
Data Structure 3964R
24
Protocol Definitions
24
Data Communication
24
Conflicts
24
Initiation of Data Communication by the High-Priority User
24
Initiation of Data Communication by the Low-Priority User
24
Retries
24
Timeout Times
24
Protocol Type 3964
25
Protocol: MODBUS-RTU
25
Notes
25
As MODBUS-Master
25
Data Structure
25
Preparation
25
As Modbus-ASCII Master
26
As MODBUS-Slave
26
Communication Sequence
26
Data Structure
26
Preparation
26
UNIGATE ® as MODBUS-Master
26
The Trigger Byte
27
The Length Byte
27
11 Hardware Ports, Switches and Leds
28
Device Labeling
28
Connectors
28
Connector to the External Device (RS-Interface)
28
Connector Supply Voltage and DEBUG-Interface
29
Ethernet 10/100 BASE/T-Connector
29
Power Supply
29
Leds
30
LED "(Ethernet) Power
30
LED "Link/Act. 10 MB" (Rev. a Only)
30
LED "Link/Act. 100 MB" (Rev. a Only)
30
LED "Full Duplex
30
Led "100 Mb
30
LED "Link/Act
30
LED "(Ethernet) State
30
LED "Power
30
LED "State
31
10Leds (Error No. / Select ID)
31
Switches
31
Termination Rx 422 + Tx 422 (Serial Interface)
31
Rotary Coding Switches S4 + S5 (Serial Interface)
31
Rotary Coding Switch S6 (Optional)
32
The Debug Cable for UNIGATE ® CL
32
12 Error Handling
33
Error Handling at UNIGATE ® CL
33
13 Installation Guidelines
34
Installation of the Module
34
Mounting
34
Removal
34
Wiring
34
Connection Systems
34
Equipotential Bonding Connection
34
Power Supply
34
Ethernet Communication Interface
35
Line Routing, Shield and Measures to Combat Interference Voltage
35
General Information on Line Routing
35
Shielding of Lines
35
14 Ethernet
37
Network-Addresses, Network-Connections
37
TCP-Connection Setup
37
Data Exchange
37
TCP or UDP
37
Data Exchange Mode
37
Direct Data Exchange
38
Modbus-Tcp
38
E-Mail
38
Server
38
FTP-Server
38
Webserver
38
File System
39
Script Update Via FTP
39
System Configuration Update Via FTP
39
UNIGATE ® -SCAN-Function
39
15 Technical Data
41
Device Data
41
Interface Data
42
16 Commissioning Guide
43
Note
43
Components
43
Installation
43
Dimensional Drawing UNIGATE ® CL - Fast Ethernet
43
Commissioning
43
Ethernet Connection
43
Connection to the Process Device
44
Shield Connection
44
Connecting the Supply Voltage
44
17 Servicing
45
Returning a Device
45
Downloading PC Software
45
18 Annex
46
Explanations of the Abbreviations
46
Hexadecimal Table
47
Advertisement
Advertisement
Related Products
DEUTSCHMANN AUTOMATION UNIGATE CL
DEUTSCHMANN AUTOMATION UNIGATE CL ProfibusDP
DEUTSCHMANN AUTOMATION UNIGATE CL - Powerlink
DEUTSCHMANN AUTOMATION UNIGATE CL - DeviceNet
DEUTSCHMANN AUTOMATION UNIGATE CL - RS
DEUTSCHMANN AUTOMATION UNIGATE CL EtherCAT
DEUTSCHMANN AUTOMATION UNIGATE CL-LONWorks Series
DEUTSCHMANN AUTOMATION UNIGATE CL-MPI
DEUTSCHMANN AUTOMATION UNIGATE CL-CANopen
DEUTSCHMANN AUTOMATION UNIGATE CL-FE
DEUTSCHMANN AUTOMATION Categories
Gateway
Microcontrollers
Controller
Network Router
Switch
More DEUTSCHMANN AUTOMATION Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL