20. EEC SYSTEM
6. Canister
6.1. Removal
1. Remove the windshield, front cover and
head light assembly.
2. Remove the canister tube set and
canister.
6.2. Inspection
Canister Evaporative Control Valve
Connect a vacuum pump to the tube of
canister. (Follow the illustration below.)
Applying 250m/mHg pressure to the
canister evaporative control valve.
If the pressure will be kept without change
obviously in one minute, that means the
valve are with good condition, otherwise
the valve malfunction, a new canister
should be replaced.
Connect a vacuum pump to the tube of
canister. (Follow the illustration below.)
Applying 45m/mHg vacuum pressure to the
canister evaporative control valve.
If the pressure will be kept without change
obviously in one minute, that means the
valve are with good condition, otherwise
represents the valve with malfunction. A new
canister should be replaced.
20-8
DT X360
Canister