6.2
Modes of Operation
The AYC-Ex5 has three modes of operation:
Normal Mode
MODE Led is green
Normal Mode is the default mode. In Normal mode the door is
locked until a Primary Code is presented to the controller. Special
codes such as Lock Strike Code and Auxiliary Code are active in
Normal mode. (See pages 38-39 for more information on the Lock
Strike and Auxiliary Codes).
Bypass Mode
MODE Led is orange
In Bypass Mode, access to the premises is dependent on whether
the controller's Lock Strike Relay is programmed for Fail Safe
Operation or Fail Secure Operation. When the Lock Strike is
programmed for Fail Secure Operation, the door is locked until the
" " button is pressed. When the Lock Strike is programmed for Fail
Safe Operation, the door is constantly unlocked.
Secure Mode
Mode Led is red
Only Secure and Master Users can a
Secured Mode.
A Secure User must enter their Primary and Secondary Codes to
gain entry. After entering their Primary Code the Door LED will flash
green for 10 seconds, during which the Secondary Code must be
entered. A Master User only needs to present their code once to
gain entry.
AYC-Ex5 family manual
Controller Functionality
Mode/Transmit
Green
Mode/Transmit
Orange
Mode/Transmit
Red
ccess the premises during the
Door/Program
Door/Program
Door/Program
Page 32