First Digit
For fail secure operation, the first digit is set to 0.
For failsafe operation, the first digit is set to 1.
Second Digit
Siren Time in minutes (1-9, 0-disabled)
Th
ird and Fourth Digits
Enter the number of seconds
you want the Lock Strike to be released.
F
or example, 0312 means Fail Secure Operation, a 3-minute Siren,
and a 12-second Lock Strike release time.
4)
System returns to its normal mode.
You will hear three beeps.
The Door LED will turn off.
The Mode LED will turn
green.
D
efining the Auxiliary Input and Output
The default auxiliary setting is 2004.
1)
Enter the Programming
Mode.
2)
Press 6 t
o enter Menu 6.
The Mode LED will flash
green
AYC-Ex5 family manual
Note:
Defau
lt value is 0004 which corresponds to Fail Secure
operation, no siren, and 4-seconds Lock Strike release time.
Controller Functionality
(from 1 to 99) that
Mode/Transmit
Mod
e/Transmit
Mode/Transmit
Door/Program
Green
Door/Program
Green
6
Door/Program
Green Green
Page 42