Lockout Feature (Keypad Tamper)

In case the controller is presented with wrong codes,
consecutively several times the unit goes into lockout mode.
When a lockout occurs, the controller keypad is de-activated so
no codes can be entered until the set lockout period expires.
During Lockout, Mode LED is Off, Door LED flashes Red, and the
controller beeps every two seconds.
6.7

Request to Exit (REX) Function

The REX Button is connected to Rosslares' secure application
appurtenance. The REX Button must be located inside the
premises to be secured and is used to open the door without the
use of a PIN code. It is usually located in a convenient location,
e.g. inside the door or at a receptionist's desk. The function of the
REX Button depends on whether the Lock Strike Relay is
programmed for Fail Safe Operation or Fail Secure Operation.
Fail Secure Operation: From the moment the REX Button is pressed,
the door will be unlocked until the Lock Strike Release Time has
passed. After this time, the door will be locked even if the REX
Button has not been released.
Fail Safe Operation: From the moment the REX Button is pressed,
the door will be unlocked until the REX Button is released, plus the
Lock Strike Release Time. In this case the Lock Strike Relay only
begins its count down once the REX Button has been released.