S-COM 6K Owner's Manual page 69

Microprocessor repeater controller
Table of Contents

Advertisement

ACCESS (with password)
Command Form:
Description:
Acknowledgement: Sends the Dialing Message
Errors:
OFF
Default Condition:
Examples:
6K V1.02 03-16-91
AUTOPATCH
(autopatch access password)(phone number)*
To access the autopatch with the Autopatch Access Password, enter the
Autopatch Access Password followed by the telephone number you wish to
dial (and the "*", if required). All digits are entered in a continuous string.
Entering only the autopatch Access Password will not result in a dial tone.
The phone number may be up to 35 digits in length, and may contain special
command digits (A, B, C, D).
Autopatch is Off
? REJ
Rejected (Number was found in Reject Table)
? ERR
Rejected (Number not allowed by Call Type)
BZ
Landline is Busy
The Autopatch Access Password defaults to 10.
Assume that the Autopatch Access Password is 10, and that the number
you wish to call is 456-7890. Enter the following:
10 4567890 *
When the above command is entered, the controller will screen the
telephone number (456-7890) according to the Call Types you have
programmed and the Accepted and Rejected Number Tables you have
programmed. If the number is acceptable, the controller will send the Dialing
Message and dial the number. If the number is not acceptable or the
Landline is busy, the controller will send one of the error messages listed
above.