Select Anti-Kerchunker Parameters
Programs the "Anti-Kerchunk" Key-up Delay and Re-Arm Delay for
the repeater.
·
Users must key for the selected length of time before the repeater transmitter
keys.
·
Once the Key-Up Delay is exceeded, the feature is disabled.
·
The anti-kerchunker is Re-Armed if no activity is present for a selected length of
time after the repeater transmitter drops.
Command Form:
Command
Select Key-Up Delay
Select Re-Arm Delay
Acknowledgment: Sends OK
Errors:
Error
? err 1
? err 2
Default Condition: Key-Up Delay is 0 seconds; Re-Arm Delay is 0 minutes
Examples:
If you want to require a one-half second key-up delay, enter:
(PW) 80 05 *
Unless changed, the anti-kerchunker will re-arm as soon as the repeater
transmitter drops. If you want a 1.5 minute delay in re-arming, enter:
(PW) 99 10 15 *
To disable the anti-kerchunker, set the key-up delay to 0:
(PW) 80 00 *
6K V2.0 12-14-01
Form
(PW) 80 xx *
(PW) 99 10 xx *
Meaning
wrong number of digits entered
illegal digit entered
166
Data Digit
xx = duration =
(00–99) = (0.0–9.9)
seconds
xx = duration =
(00–99) = (0.0–9.9)
minutes