RECEIVER #2-TO-TRANSMITTER PATH
Command Form:
Description:
Acknowledgement: OK
Errors:
? ERR 1
Default Condition:
6K V1.02 03-16-91
REPEATER OPERATION
(PW) 63 82 (0=off/1=on) *
This command determines whether Receiver #2 will be used as a link
receiver or as a control receiver.
If the Receiver #2-to-Transmitter Path is turned on, then Receiver #2 will act
as a link receiver. This means that Receiver #2 will drive the repeater
transmitter and the DTMF decoder, but on a low priority basis.
If the Receiver #2-to-Transmitter Path is turned off, then Receiver #2 will act
as a control receiver. This means that Receiver #2 will not drive the repeater
transmitter, but it will drive the DTMF decoder as its highest-priority source.
wrong number of digits entered
? ERR 2
illegal digit entered
off
Receiver #2 acts as a Control Receiver