S-COM 6K Owner's Manual page 63

Microprocessor repeater controller
Table of Contents

Advertisement

PROGRAMMABLE MESSAGES
Command Form:
Description:
Acknowledgement: OK
Errors:
? ERR 1
Default Conditions: Courtesy Message
Examples:
6K V1.02 03-16-91
MESSAGE COMMANDS
Courtesy Message
Dropout Message
Pre-Timeout Message
Post-Timeout Message
Initial ID Message
Normal ID Message
Impolite ID Message
Autopatch Dialing Message
Autopatch Timeout Warning Message
Reverse Patch Ringout Message
This series of commands is used to change the various messages sent by
the controller. Enter the password, followed by the 4-digit root number
shown, followed by the desired message. Any message may have any
combination of message types, including CW, beeps, page tones, etc. The
maximum size of any message is 50 bytes (50 2-digit codes). You must
count the Control Character. Therefore, any message could have 46 CW
characters max, etc. To delete a message, enter the password, the 4-digit
root number, and the "*" (do not enter any message).
too many digits entered
? ERR 2
illegal digit entered
Dropout Message
Pre-Timeout Message
Post-Timeout Message
Initial ID Message
Normal ID Message
Autopatch Dialing Message
Autopatch Timeout Warning Message
Landline Answer Message
Reverse Patch Ringout Message
Let's change the Normal ID Message to "W0XYZ/R" in CW. It is a good idea
to preface any CW message with the CW Control Character, 9900. Now,
looking up "W0XYZ/R" in the CW Character Set table, we find 32 00 33 34
35 38 27. The entire command to change the Normal ID Message looks like
this:
(PW) 31 31 9900 32 00 33 34 35 38 27 *
(The spaces are used to illustrate how the command works. The command
(PW) 31 10 (msg) *
(PW) 31 13 (msg) *
(PW) 31 16 (msg) *
(PW) 31 19 (msg) *
(PW) 31 30 (msg) *
(PW) 31 31 (msg) *
(PW) 31 32 (msg) *
(PW) 31 40 (msg) *
(PW) 31 41 (msg) *
(PW) 31 51 (msg) *
60 ms, 440 Hz beep (74 09)
(none)
TO
TO
ID
ID
AS ("wait")
AR ("end-of-msg")
3 beeps (74 09 21 33)
55 (CW)
62

Advertisement

Table of Contents
loading

Related Products for S-COM S-COM 6K

Table of Contents