Select Receiver Activity-Triggered Macros
Select Receiver Post-Activity Timers
Allows the programmer to execute macros based on activity detected
by the receivers.
Receiver Post-Activity Timers delay the macro execution for a
programmable length of time after last activity.
· Each receiver has its own Start-of-Activity Macro, Post-Activity Macro, and
Post- Activity Timer.
· The Receiver Post-Activity Timer starts each time receiver activity ends.
When the timer expires, the macro associated with the receiver is executed.
The timers require two data digits representing the delay. "00-99" equals
0.0-9.9 minute delay.
· These macros execute based solely on receiver activity, and act
independently of the transmitter paths that the receivers drive.
· Be sure to set the corresponding receiver access mode for Receiver 1
Command Form:
Command
Select RX1 Start-of-Activity Macro
Select RX1 Post-Activity Macro
Select RX2 Start-of-Activity Macro
Select RX2 Post-Activity Macro
Select RX1 Post-Activity Timer
Select RX2 Post-Activity Timer
Acknowledgment: Sends OK
Errors:
Error
? err 1
? err 2
Default Condition: No macros are assigned; Timers are 1.0 minute
Examples:
These macros execute based solely on receiver activity, and act independently
of the transmitter paths that the receivers drive. The setting of the
6K V2.0 12-14-01
Form
(PW) 26 67 (macro name) *
(PW) 26 68 (macro name) *
(PW) 26 69 (macro name) *
(PW) 26 70 (macro name) *
(PW) 99 00 xx *
(PW) 99 01 xx *
Meaning
wrong number of digits entered
illegal digit entered
167
Data Digit
not applicable
not applicable
not applicable
not applicable
xx = duration = 00–
99 = 0.0–0.0 minutes
xx = duration = 00–
99 = 0.0–0.0 minutes