Troubleshooting Checklist - Cabletron Systems 2E48-27R User Manual

Cabletron systems user's guide switch 2e48-27r/2e49-27r
Hide thumbs Also See for 2E48-27R:
Table of Contents

Advertisement

Chapter 4: Troubleshooting
4.3

TROUBLESHOOTING CHECKLIST

If the 2E4X-27R is not working properly, refer to
of possible problems, causes, and recommended actions to resolve the
problem.
Problem
All LEDs are OFF.
No Local
Management
Password screen.
Cannot contact the
device from in-band
management.
Port(s) goes into
standby for no
apparent reason.
User parameters (IP
address, Device and
Module name, etc.)
were lost when the
2E4X-27R power
was cycled or the
front panel RESET
button was pressed.
4-6
Table 4-4 Troubleshooting Checklist
Possible Cause
Loss of power.
Installed improperly.
Autobaud is enabled, but
the baud rate has not yet
been sensed.
Terminal setup is not
correct.
Improper console cable
pinouts.
Improper Community
Names Table.
IP address not assigned. Refer to
Port is disabled.
No link to device.
Loop condition detected.
Mode switch (7), NVRAM
Reset, was changed
sometime before either
cycling power or
pressing the RESET
button causing the
user-entered parameters
to reset to factory default
settings.
Table 4-4
Recommended Action
Check for proper connection
of the power cable and its
access to a live outlet.
Check the installation.
Press ENTER (RETURN)
(may take up to four times).
Refer to
Chapter 5
setup procedures.
Refer to Appendix A for
proper console port pinouts.
Refer to
Chapter 5
for Community Names Table
setup.
Chapter 5
address assignment
procedure.
Enable port.
Check link to device.
1. Review network design
and delete unnecessary
loops.
2. Call the Cabletron Systems
GCC if the problem
continues.
1. Reenter the lost
parameters as necessary.
2. Call the Cabletron Systems
GCC if the problem
continues.
2E48-27R/2E49-27R User's Guide