Appendix B: FE-100TX, FE-100FX, and FE-100F3 Specifications
B.3
FE-100F3
The FE-100F3 shown in
supports single mode fiber optic cabling. Specifications for the FE-100F3
are listed in
Table
Cable Type
8/125 µm fiber optic
12.5/125 µm fiber optic
The transmitter power levels and receive sensitivity levels listed
NOTE
are peak power levels after optical overshoot. A peak power
meter must be used to correctly compare the values given
above to those measured on any particular port. If power levels
are being measured with an average power meter, add 3 dB to
the measurement to compare the measured values to the
values listed above.
B-4
Figure B-3
B-2, below.
Figure B-3 FE-100F3
Table B-2 Transmitter Power
Worst Case Budget
>10.0 dB
>10.0 dB
uses an SC style connector that
Typical Budget
2E48-27R/2E49-27R User's Guide
19601-68
<10.0 dB
<10.0 dB