Configuring The Trap Table - Cabletron Systems 2E48-27R User Manual

Cabletron systems user's guide switch 2e48-27r/2e49-27r
Hide thumbs Also See for 2E48-27R:
Table of Contents

Advertisement

Enable Traps (Toggle)
Enables transmission of the traps to the network management station with
the associated IP address. This field toggles between YES and NO.
5.9.1
Configuring the Trap Table
To configure the Trap table, proceed as follows:
1.
Use the arrow keys to highlight the appropriate Trap Destination
field.
2.
Enter the IP address of the workstation that is to receive traps. IP
address entries must follow the DDN format.
For example: 134.141.79.121
3.
Press ENTER. If an invalid entry is entered, the message "INVALID
IP ENTERED" displays in the Event Message Line.
4.
Use the arrow keys to highlight the Trap Community Name field.
Enter the community name.
5.
Press ENTER.
6.
Use the arrow keys to highlight the Enable Traps field. Press the
SPACE bar to choose either YES (send alarms from the 2E4X-27R to
the workstation), or NO (prevent alarms from being sent).
7.
Use the arrow keys to highlight the SAVE command and press
ENTER. The message "SAVED OK" displays on the screen.
Exiting without saving causes a "NOT SAVED?" message to
NOTE
appear above the SAVE command. Edits are lost if they are not
saved before exiting.
The designated workstations now receive traps from the 2E4X-27R.
2E48-27R/2E49-27R User's Guide
SNMP Traps Screen
5-37