Connecting A Utp Segment To The Fe-100Tx - Cabletron Systems 2E48-27R User Manual

Cabletron systems user's guide switch 2e48-27r/2e49-27r
Hide thumbs Also See for 2E48-27R:
Table of Contents

Advertisement

Chapter 3: Installation
4.
At the other end of the fiber optic cable, attach the fiber pair to the
transmit and receive ports of the device.
.
Receive (RX) LED
5.
Verify that a link exists by checking that the port RX LED is on
(flashing amber, blinking green, or solid green). If the RX LED is off,
perform the following steps until it is on:
a.
Verify that the device at the other end of the segment is ON and
connected to the segment.
b.
Check the crossover of the cables. Swap the cable connections if
necessary.
c.
Check the cable for continuity.
d.
Check that the fiber optic connection meets the dB loss and cable
specifications outlined in
multimode or single mode cabling, respectively.
If a link is not established, contact Cabletron Systems Global Call Center.
Refer to
Section 1.5
6.
Repeat steps 1 through 5, above, until all connections have been made.
3.4.2

Connecting a UTP Segment to the FE-100TX

To ensure proper operation, use only Category 5 Unshielded
NOTE
Twisted Pair (UTP) cabling that has an impedance between 85
and 111 ohms.
3-10
RX
TX
Figure 3-6 Fiber Optic Connection
for details.
Section 2.2
or
Section 2.3
2E48-27R/2E49-27R User's Guide
23141-07
for

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF