Vertical Inline Power Flue Terminations Rigid Pipe - Regency Fireplace Products Greenfire GF950L Owners & Installation Manual

Hide thumbs Also See for Greenfire GF950L:
Table of Contents

Advertisement

installation
Vertical Inline Power Vent Terminations
VERTICAL INLINE POWER FLUE TERMINATIONS
RIGID PIPE
Rigid Pipe
The minimum components required when using inline power
flue are:
1
High Wind Cap
1
Rigid Pipe Adaptor
1
Ceiling Firestop
1
Flashing
1
Storm Collar
1
Lengths of pipe to suit wall thickness & vent run
(see chart)
1
Inline Power Flue Kit
Galvanized pipe is desirable above the roofline due to its higher
corrosion resistance. Continue to add pipe sections through the
flashing until the height of the vent cap meets the minimum height
requirements specified in table below or local codes. Note that for
steep roof pitches, the vertical height must be increased. A poor
draft, or down drafting can result from high wind conditions near
big trees or adjoining roof lines, in these cases, increasing the
vent height may solve the problem.
Roof Pitch
Minimum Flue Height
Roof Pitch
Minimum Vent Height
Meters
Feet
flat to 30.26
0.61
o
flat to 7/12
2
over 30.26
to 33.69
0.61
o
o
over 7/12 to 8/12
2
over 33.69
to 36.37
0.61
o
o
over 8/12 to 9/12
2
over 36.37
to 39.81
0.76
o
o
over 9/12 to 10/12
2.5
over 39.81
to 42.51
0.99
o
o
over 10/12 to 11/12
3.25
over 42.51
to 45.00
1.22
o
o
over 11/12 to 12/12
4
over 45.00
over 12/12 to 14/12
o
to 49.40
o
1.52
5
over 49.40
o
to 53.13
o
1.83
over 14/12 to 16/12
6
over 16/12 to 18/12
7
over 53.13
to 56.31
2.13
o
o
over 18/12 to 20/12
7.5
over 56.31
to 59.04
2.29
o
o
over 20/12 to 21/12
8
over 59.04
to 60.26
2.44
o
o
The FPI AstroCap
TM
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
Metal Products Ameri Vent Direct Vent, Security Secure Vent
of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
48
920-210
Inline Power Vent Vertical or Horizontal Installation Instructions
Meters
0.61
0.61
0.61
0.76
0.99
1.22
1.52
1.83
2.13
2.29
2.44
, ICC Excel,
®
Inline Power Flue Kit
Olympia Ventis DV,
Selkirk Direct-Temp. AstroCap
3
High Wind Cap
Storm Collar
Flashing
(not supplied)
Ceiling Firestop
Lengths of Pipe
Slip Section
Lengths of Pipe
Rigid Pipe Adaptor
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must
be used to secure rigid pipe to
adaptor.
®
Direct Vent, American
is a proprietary trademark
TM
Regency GF950L-2 Gas Fireplace
GF950PV
02.20.20

Advertisement

Table of Contents
loading

Table of Contents