Flueing Arrangements - Horizontal Termination (Flex) - Regency Fireplace Products Greenfire GF950L Owners & Installation Manual

Hide thumbs Also See for Greenfire GF950L:
Table of Contents

Advertisement

installation
FLUEING ARRANGEMENTS (NON POWER FLUE)
HORIZONTAL TERMINATION (FLEX)
Regency
Direct Vent System
®
These flueing systems, in combination with GF950L, have been tested and listed as a Direct Vent system by IAPMO. The location of the termination cap must
conform to the requirements in the Flue Terminal Locations diagram from the "Exterior Flue Termination Locations" section.
Regency
®
Direct Vent (Flex) System Termination Kits include all the parts needed to install the GF950L using a flexible flue.
FPI Kit #
Length
Contains:
#946-515
1.2 m
1)
2)
3)
4)
5)
#946-516
3 m
6)
7)
8)
9)
Notes:
1. Liner sections should be continuous without any joints
or seams.
2. Only Flex pipe purchased from Regency® may be used
for Flex installations
3. Horizontal flue must be supported every 0.9m.
4. Regency® Direct Vent System (Flex) is only approved
for horizontal terminations.
5. Flex system can only be used up to a maximum continu-
ous flue length of up to 3m. If longer runs are required,
rigid pipe must be used.
NOTE: Maximum horizontal run: 3m
28
168mm flexible outer liner (Kit length)
102mm flexible inner liner (Kit length)
spring spacers
thimble
AstroCap termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 1-1/2" drill point
102mm
Flue Guard - if required*
(Part #946-506/P)
Regency GF950L-2 Gas Fireplace