WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use petrol or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
919-840
GF950L
®
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
MODELS: GF950L-NG
GF950L-LP
GF950L-ULPG
LISTINGS AND CODE APPROVALS
These gas appliances have been tested
in accordance with AS 5263.0, AS/NZS
5263.1.3 and have been certified by the
Australian Gas Association for installation and
operation as described in these Installation
and Operating Instructions.
Must be installed as per AS/NZS5601
Your unit should be serviced annually by
an authorised service person.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
06 June 2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GF950L-NG and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency Fireplace Products GF950L-NG

  • Page 1 Greenfire GF950L ® Owners & Gas Fireplace Installation Manual MODELS: GF950L-NG GF950L-LP GF950L-ULPG LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AS 5263.0, AS/NZS 5263.1.3 and have been certified by the Australian Gas Association for installation and operation as described in these Installation and Operating Instructions.
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The GF950L has been designed to provide you ® with all the warmth and charm of a wood fireplace at the flick of a switch. The model GF950L has been approved by AGA for both safety and efficiency.
  • Page 3: Table Of Contents

    table of contents Vertical terminations ............31 Copy of Data Badge ............4 Rigid Pipe 4" x 6-5/8" (102mm x 175mm) ....31 Unit Dimensions ............5 Flueing Arrangement for Vertical Terminations ....32 Important Message ............6 Direct flue zero Clearance top exit vertical flue Kit General Safety Information ..........6 Installation instructions GF950 ........33 Installation Checklist ............7...
  • Page 4: Copy Of Data Badge

    Regency Gas Fireplace Distributed by: Model Western Australia: Air Group Australia ULPG Gas Type 28 Division St Welshpool, WA 6106 Model GF950L-NG GF950L-LP GF950L-ULPG Eastern Australia 35 MJ/hr 28 MJ/hr 28 MJ/hr Gas Consumption High Fireplace Products Australia Pty. Ltd.
  • Page 5: Unit Dimensions

    dimensions DIMENSIONS UNIT DIMENSIONS 500mm 1091mm 560mm 996mm 523mm 14mm 890mm Unit shown with Black Flat Fascia 996mm 1192mm 989mm 990mm 1000mm 1034mm Unit with Finishing Trim - Flush Finish Black Premium Glass Fascia Regency GF950L Gas Fireplace...
  • Page 6: Important Message

    installation IMPORTANT MESSAGE YOUNG CHILDREN SHOULD BE 11. Under no circumstances should this appliance SAVE THESE be modified. Parts that have to be removed CAREFULLY SUPERVISED WHEN for servicing should be replaced prior to THEY ARE IN THE SAME AREA AS INSTRUCTIONS operating this appliance.
  • Page 7: Installation Checklist

    installation INSTALLATION CHECKLIST This includes: 4. The GF950L Direct Vent Gas Fireplace is approved for alcove installations, see "Clear- 1) Clocking the appliance to ensure the correct ances" section for details. 1. Locate appliance: firing rate (rate noted on label) after burning a) Room location (Refer to "Locating Your appliance for 15 minutes.
  • Page 8: Clearances

    installation CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Caution Requirements WARNING Fire hazard is an extreme risk...
  • Page 9: Framing Dimensions

    installation FRAMING DIMENSIONS Framing Description GF950 Dimensions Framing Height 940mm combustible finish ¹ Framing Height -Steel Stud 756mm non combustible steel stud Framing Width 1127mm Framing Depth 552mm Minimum Height to Combustibles 1156mm Corner Wall Depth 1273mm Corner Facing Wall Width 1800mm Vent Centerline Height 991mm...
  • Page 10: Combustible Finishing

    installation COMBUSTIBLE FINISHING UNIT ASSEMBLY/ FINISHING/ MANTEL CLEARANCES + MANTEL LEG CLEARANCES UNIT ASSEMBLY PRIOR TO INSTALLATION The nailing strips must be correctly positioned and attached before unit is slid into position. NAILING STRIPS-COMBUSTIBLE FINISHING The nailing strips come attached to the unit. There is 1 plate on each side, 1 on the top.
  • Page 11: Framing & Finishing (Combustible)

    installation FRAMING & FINISHING (COMBUSTIBLE) Note: Finished *Finishing Trim or one of the fascias must be used with com- Material bustible finishing. 10mm to 19mm combustible finishing can be used if the 13mm 1st slot 0mm-19mm thick- air gap around the front facing of the unit is maintained. Finishing ness using combus- material cannot be thicker than 19mm and must be flush with the tible finishing...
  • Page 12: Clearances For Combustible Finishing With Mantel

    installation CLEARANCES FOR COMBUSTIBLE FINISHING WITH MANTEL Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible finishing and mantel clearances are shown in the diagram on the right. Finishing Trim must be used with combustible finishing. (305mm) (152mm) Note: Maximum combustible finishing material thickness is 19mm...
  • Page 13: Unit Assembly/ Finishing/ Mantel Clearances + Mantel Leg Clearances

    installation NON COMBUSTIBLE FLUSHED FINISHING UNIT ASSEMBLY/ FINISHING/ MANTEL CLEARANCES + MANTEL LEG CLEARANCES REMOVE TOP NAILING STRIPS & STANDOFFS Remove the top nailing strip/standoff by removing 4 screws in locations shown in Diagram to the right, then lift off and recycle. Break off the 7 standoffs with a pair of pliers.
  • Page 14: Clearances For Non-Combustible Flushed Finishing With Mantel

    installation CLEARANCES FOR NON-COMBUSTIBLE FLUSHED FINISHING WITH MANTEL Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. (305mm) (152mm) Note: For a flushed finish using non-combustible finishing, seven 13mm stand-off tabs around the fireplace opening must be broken off.
  • Page 15: Flushed Finishing & Framing With Non-Combustible Material

    installation FLUSHED FINISHING & FRAMING WITH NON-COMBUSTIBLE MATERIAL Note: For flush finishing, the top nailing strip must be removed and a non- * diagrams shown below are Finished combustible steel stud support added. with top nailing strip removed. Material The seven fireplace opening standoffs which are located on this unit can be removed when non combustible material is installed flush with the unit.
  • Page 16: Zero Clearance Box Framing Dimensions

    installation ZERO CLEARANCE BOX FRAMING DIMENSIONS Note: Fascia Part no. 468-911 must be used with optional mock fireplace. Framing dimension Description GF950L Framing Height 1267mm Framing Width 1127mm Framing Depth 560mm Minimum Raised Height 100mm Corner Wall Depth 1564mm Corner Facing Wall Width 2212mm Gas Connection Opening Height 38mm...
  • Page 17: Zero Clearance Box Framing And Combustible Requirements

    installation ZERO CLEARANCE BOX FRAMING AND COMBUSTIBLE REQUIREMENTS The following material thicknesses may be accommodated by installing the Faceplate on slot 1, 2 or 3: 1= 10-12mm 2= 16-18mm 3 = 22-24mm Material Thickness 1 2 3 Slots Faceplate Unit 1073mm 841mm 941mm...
  • Page 18: Zero Clearance Box Installation

    installation ZERO CLEARANCE BOX INSTALLATION 1. Depending on which way the unit will be vented -- remove either the top 3. Secure the box to the framing with 2 screws on each side centre or back knockout. and the 2 holes on the base of the box. Knockouts 4.
  • Page 19: Installing A Tv / Artwork Flush With The Unit

    installation INSTALLING A TV / ARTWORK FLUSH WITH THE UNIT Note: All wiring should stay free and clear of the vent system to avoid damage due to heat, if located directly in front of the vent system. Ensure wiring is secured without any sag. Heat deflector must overhang front of TV by 51mm.
  • Page 20: Installing A Tv / Artwork Enclosed Above The Unit

    installation INSTALLING A TV / ARTWORK ENCLOSED ABOVE THE UNIT Maximum recess is 146mm.” Minimum height is 370mm from top lip. " 146mm DETAIL M SCALE 1 : 6 Ensure framing does not interfere with venting Regency GF950L Gas Fireplace...
  • Page 21: Optional Framing Kit

    GF950 installation OPTIONAL FRAMING KIT OPTIONAL FRAMING KIT 1. Construct the timber framing, ensure inside dimensions are 940mm H x 1127mm W as shown below. 1127mm (468-025) 940mm Flat side out 5. Secure horizontal steel header stud (468-039) with 2 screws per side as per diagram.
  • Page 22: Non Combustible Facing Installation

    7. Paint walls using a high quality paint which will withstand the high Discoloration is not the responsibility of Regency Fireplace Products, temperatures being emitted from this appliance. we believe careful attention to the recommendations provided here will be result in aesthetically pleasing result free of issues outlined above.
  • Page 23: Framing & Finishing (Clean Finish Installations Only)

    installation FRAMING & FINISHING (CLEAN FINISH INSTALLATIONS ONLY) 1. Frame in the enclosure for the unit with framing material. IMPORTANT: The framed opening must be of non-combustible material. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed.
  • Page 24: Exterior Flue Termination Locations

    installation EXTERIOR FLUE TERMINATION LOCATIONS FIGURE 6.2 (in part): LOCATION OF FLUE TERMINALS OF BALANCED FLUE AS/NZ 5601, ROOM-SEALED, FAN ASSISTED OR OUTDOOR APPLIANCE Regency GF950L Gas Fireplace...
  • Page 25: Clearances

    installation CLEARANCES Minimum clearances (mm) Ref. Item Natural Draught Assisted Below eaves, balconies and other projections: Appliances up to 50 MJ/h input Appliances up to 50 MJ/h input From the ground, above a balcony or other surface* From a return wall or external corner* From a gas meter (M) (see Note 5) (see Clause 5.11, 5.9 for vent terminal location of regulator) 1000...
  • Page 26: Flue Restrictor Position

    installation FLUE RESTRICTOR POSITION FLUE RESTRICTOR SETTING Flue restriction is required for certain venting installations, see the diagrams in the "Flueing Arrangements" section to determine if they are required for your installation. The Flue Restrictor plate is located on the inside top of the firebox. Set 3 - 18mm open To set the flue restriction as indicated in the flueing arrangements diagrams, refer to the following instructions;...
  • Page 27: Flueing Introduction

    installation FLUEING INTRODUCTION The GF950L uses the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney. Note: These flue pipes must not be connected to any other appliance.
  • Page 28: Flueing Arrangements

    installation FLUEING ARRANGEMENTS HORIZONTAL TERMINATION (FLEX) Regency Direct Vent System ® These flueing systems, in combination with GF950L, have been tested and listed as a Direct Vent system by AGA. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram from the "Exterior Flue Termination Locations" section. Regency Direct Vent (Flex) System Termination Kits includes all the parts needed to install the GF950L using a flexible vent.
  • Page 29: Horizontal Terminations

    installation HORIZONTAL TERMINATIONS RIGID PIPE 4" X 6-5/8" (102MM X 175MM) The minimum components required for a basic horizontal termination are: Horizontal Termination Cap Elbow Rigid Pipe Adaptor (510-994) Wall Thimble Length of pipe to suit wall thickness (see chart) Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap.
  • Page 30: Horizontal Terminations

    installation HORIZONTAL TERMINATIONS RIGID PIPE 4" X 6-5/8" (102MM X 175MM) The diagrams below shows examples of horizontal termination arrangements using one 90 elbow. 1) A maximum of one 90 or two 45 elbows is permitted. 2) Minimum distance between elbows is 305mm. •...
  • Page 31: Vertical Terminations

    installation VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" (102MM X 175MM) The minimum components required for a basic vertical termination using Simpson Duravent Rigid Flue System are: Vertical Termination Cap Rigid Pipe Adaptor (510-994) High wind cap Flashing Storm Collar Length of pipe to suit height requirement (see chart) Flashing...
  • Page 32: Flueing Arrangement For Vertical Terminations

    installation FLUEING ARRANGEMENT FOR VERTICAL TERMINATIONS Vertical Venting with Two (2) 45 Elbows Metres The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two elbow, with Rigid Pipe Flueing Systems. •...
  • Page 33: Direct Flue Zero Clearance Top Exit Vertical Flue Kit Installation Instructions Gf950

    installation DIRECT FLUE ZERO CLEARANCE TOP EXIT VERTICAL FLUE KIT INSTALLATION INSTRUCTIONS GF950 This flue kit has been manufactured for use with GF950L and to be installed in accordance with AS/NZS 5601. To ensure safety and correct unit operation this flue kit must be installed as outlined in these instructions. Heater and flue clearances from combustible materials must be in accordance with these instructions and AS/NZS 5601.
  • Page 34: Unit Installation With Horizontal Termination

    installation UNIT INSTALLATION WITH HORI- 5) Assemble the desired combination of pipe and 7) Ensure that the pipe clearances to combustible elbows to the appliance flue outlets and secure. materials are maintained (Diagram 5). Install ZONTAL TERMINATION the termination cap. 102MM X 175MM FLUEING (Rigid Flue Systems) Note: If installing termination on a siding...
  • Page 35 installation ASTROCAP UNIT INSTALLATION WITH HORI- 5) Slip the assembled liner and termination DIMENSIONS (946-523/P) ZONTAL TERMINATION assembly through the thimble making sure the 102MM X 175MM FLUEING termination cap faces up (there are markings (Flex Flue Systems) on the cap indicating which way is up). This will position the termination cap with proper down Minimum Flue Clearances slope for draining water.
  • Page 36: Unit Installation With Vertical Termination

    installation UNIT INSTALLATION WITH VERTI- 4. Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2. The hole CAL TERMINATION should be of sufficient size to meet the minimum requirements for clearance to combustibles of 102MM X 175MM FLUEING Flue Height 38mm.
  • Page 37: High Elevation

    PILOT ADJUSTMENT GF950L-NG SYSTEM DATA NOTE: The outlet pressure must be set to maximum 2.49 kPa for both LP/ULPG and 0.87 kPa for NG. Min. Supply Pressure 1.13 kpa Periodically check the pilot flames. Correct flame pattern has two strong blue flames: 1 flowing Low Setting Man.
  • Page 38: Wiring Diagram

    installation WIRING DIAGRAM DISCONNECT POWER SUPPLY TO UNIT PRIOR TO WORKING ON ELECTRICAL COMPONENTS. ORANGE BLUE MODULATING VALVE GREEN ORANGE COIL PRESSURE SWITCH SPARKER BROWN SIGMA 845 (NO) MODULE - SPARK PILOT FLAME MODULE - FLAME SENSOR SIT 201 IGNITION MODULE MODULE - EARTH GREEN BLACK...
  • Page 39: I.t. Valve Description

    installation 845 S.I.T. VALVE DESCRIPTION 1) On-Off Solenoid Valve EV1 2) On-Off Solenoid Valve EV2 3) Inlet Pressure Test Point 4) Outlet Pressure Test Point 5) Connection for Pressure Regulator/Combustion Chamber Compensation 6) Pressure Regulator for Minimum and Maximum Outlet Pressure 7) Gas Outlet Pressure Electric Modulator 8) Pilot Outlet 9) Main Gas Outlet...
  • Page 40: Optional Fan Ducting Kit Installation

    installation GF950 OPTIONAL FAN DUCTING KIT INSTALLATION OPTIONAL FAN DUCTING KIT INSTALLATION LISTINGS AND CODE GENERAL INFORMATION Maximum Duct Run: 9.0m Kit Contains 4.5m APPROVALS The Fan Kit increases the eff ectiveness of your fi replace by dispersing warm air from the fi replace If you require more than 4.5m please purchase Fan This Fan Kit has been approved for use with GF950.
  • Page 41: Optional Fan Kit Installation

    installation GF950 OPTIONAL FAN KIT INSTALLATION OPTIONAL FAN KIT INSTALLATION NOTE: Installation of Fan Kit should be done prior Air Duct to installation of the wall. 2. Mount and secure the fan housing assembly to framing members, the front of the fan housing will protrude 12.7mm out of the wall so it may be fi...
  • Page 42: Fan Duct Extension Kit Installation

    GF950 installation OPTIONAL FAN KIT INSTALLATION FAN DUCT EXTENSION KIT INSTALLATION FAN DUCT EXTENSION KIT In order to use the fan extension duct kit, you must have fan kit. This kit allows you to extend the fan duct to 9m. 1.
  • Page 43: Log Set Installation

    gF900 installation LOG SET INSTALLATION Log Set InStaLLatIon Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
  • Page 44 GF900 installation 7. Position Log 6 to rest on Log 1 and Log 3 as shown in Diagram 9. 4. Rest Log 4 on Log 1 and Ceramic Log Burner as shown in Diagram 6. Diagram 9 Diagram 6 8. Line up locator on bottom of Log 7 with locator on Ceramic Log Burner as shown in Diagram 10.
  • Page 45: Front Trim Removal / Installation

    installation FRONT TRIM REMOVAL / INSTALLATION 1. Remove faceplate, inner door frame, and glass door if already installed - see instructions in this manual. 2. Remove two (2) screws in locations shown below to remove front trim piece. 3. Reverse steps to reinstall. Front Trim Piece Diagram 1 - Front Trim Screw Locations INNER PANEL REMOVAL / INSTALLATION...
  • Page 46: Faceplate And Deflector Installation

    GF900 installation FACEPLATE AND DEFLECTOR INSTALLATION FACEPLATE AND DEFLECTOR INSTALLATION 4 screws 1. Install the fascia to the unit by hooking the left and right side mounting brackets into the mounting slots at the side ofthe firebox as shown below. Diagram 4 3 Mounting Slots Diagram 1...
  • Page 47: Screen & Inner Door Frame Installation

    GF900 installation SCREEN & INNER DOOR FRAME INSTALLATION SCREEN & INNER DOOR FRAME INSTALLATION 1. Hang Screen Mesh over Inner Door Frame as shown in Diagram 1. 3. Install Screen and Inner Door Frame to unit over glass door frame as shown in Diagram 3.
  • Page 48: Optional Finishing Trim Installation

    installation GF900 GLASS SURROUND INSTALLATION Install the fascia to the unit by hooking the left and right side mounting brackets into the mounting slots at the side of the fi rebox as shown below. It is recommended that you use the fi rst mounting slot (the one closest to the door frame overlay) out of the 3 so that the faceplate and door frame overlay are fl...
  • Page 49: Operating Instructions

    operating instructions SUMMARY OF OPERATING CONTROLS INSTRUCTIONS FIRST FIRE On/Off Button Before operating this appliance, proceed through The FIRST FIRE in your heater is part of the If the unit is switched off, pressing and releasing the following check list. paint curing process.
  • Page 50: Copy Of Lighting Plate Instructions

    operating instructions COPY OF LIGHTING PLATE INSTRUCTIONS RESETTING THE UNIT NORMAL OPERATING SOUNDS FOR YOUR SAFETY READ BEFORE LIGHTING GAS APPLIANCES If the appliance goes to 'lockout', the system SUITABLE ONLY FOR INDOOR INSTALLATION This appliance must be installed in accordance will have to be reset by depressing the reset with local codes, if any;...
  • Page 51: Fan Service

    maintenance FAN SERVICE PRIOR TO SERVICING THE FAN, ENSURE UNIT HAS COOLED TO 6. Remove access panel by removing eight(8) screws in locations ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS shown in Diagram 4. SUPPLY IS TURNED OFF. 1. Remove faceplate, inner frame, glass door, front trim piece and inner panels - see instructions in this manual.
  • Page 52: Maintenance Instructions

    maintenance MAINTENANCE INSTRUCTIONS GENERAL FLUE GLASS GASKET MAINTENANCE 1. Always turn off the gas valve before cleaning. If the glass gasket requires replacement use a Conduct an inspection of the venting system For relighting, refer to lighting instructions. tadpole glass gasket (Part # 936-157). semi-annually.
  • Page 53: Troubleshooting

    maintenance TROUBLESHOOTING All maintenance must be carried out by a licensed qualified service person IT IS CRITICAL THAT THIS APPLIANCE IS EARTHED AND THAT THE ACTIVE AND NEUTRAL ARE NOT REVERSED UNIT OPERATION ACTION REQUIRED No gas to the burner The gas valve should open at the same time the ignition commences sparking.
  • Page 54: Glass Door Installation

    maintenance GLASS DOOR INSTALLATION WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person. Glass should be cool if cleaning is necessary. 1.
  • Page 55: Valve Tray Replacement

    maintenance VALVE TRAY REPLACEMENT 6. Remove burner by removing 14 screws in locations shown below. PRIOR TO VALVE TRAY REPLACEMENT, ENSURE UNIT HAS COOLED TO ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS SUPPLY IS TURNED OFF. 1. Remove faceplate, inner frame, glass door, front trim piece and inner panels - see instructions in this manual.
  • Page 56: Electronic Components Parts List

    parts list PARTS LIST ELECTRONIC COMPONENTS PARTS LIST Note: Depending on the model, the diagram below may not be exactly as shown - for reference purposes only. 910-936 910-082 911-258 NG 911-259 LP 910-089 910-088 910-912 910-084 910-101 910-526 910-080 911-183 910-514 910-083...
  • Page 57: Main Assembly

    parts list PARTS LIST MAIN ASSEMBLY W840470 Pilot Assembly Gasket 936-170 Burner Orifice Gasket 911-101 Control Box ECS III 911-113 Switch On/Off W/CAT 5 Cable 3 FT (105C) 911-112 Pressure Switch MPL-9370-0.20-DEACT 911-142 Wire Harness ECS IP 911-121 Module SIT 230V (DV) 0.579.204 910-912 Wire Harness - From Module To Valve 466-014...
  • Page 58 parts list PARTS LIST MAIN ASSEMBLY Regency GF950L Gas Fireplace...
  • Page 59: Accessories

    parts list PARTS LIST ACCESSORIES Part # Description 32 467-922 Inner door frame - Black w/ Screen 467-932 Inner door frame - Stainless w/ Screen 467-926 Inner door frame Gloss Black w/Screen 33 467-544 Door Frame Overlay - Black 34 468-934 Fascia and Door Frame Black w/Screen 468-936 Fascia and Door Frame Stainless Steel w/Screen...
  • Page 60 notes NOTES Regency GF950L Gas Fireplace...
  • Page 61: Warranty

    WARRANTY warranty Limited Lifetime Warranty FPI Fireplace Products International Ltd. (“the manufacturer”) through its wholly owned subsidiary, Fireplace Products Australia Pty Ltd (for Australia and New Zealand customers) and sold under the Regency® brand of fireplace products (collectively referred to herein as “FPI”), extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation.
  • Page 62 WARRANTY warranty part is returned to the distributor, dealer or agent for inspection if requested by FPI. Alternatively, FPI may at its own discretion fully discharge all of its obligations under the warranty by refunding the verified purchase price of the product to the original purchaser.
  • Page 63 WARRANTY warranty FPI has no obligation to enhance or modify any unit once manufactured (i.e. as products evolve, field modifications or upgrades will not be performed on existing appliances). Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty.
  • Page 64 WARRANTY warranty Limitations of Liability: 1. Exclusion of implied terms The customer may have the benefit of consumer guarantees under the Australian Consumer Law. To the maximum extent permitted by law, all terms, conditions or warranties that would be implied into this Warranty or in connection with the supply of any goods or services by the supplier under law or statute or custom or international conventions are excluded.
  • Page 65 WARRANTY warranty How to Obtain Warranty Service: Customers should contact the authorised selling dealer to obtain warranty service. In the event the authorised selling dealer is unable to provide warranty service, please contact FPI by mail at the address listed below. Please include your name, address, purchase date, selling dealer, serial #, type of unit, a brief description of the problem, email and telephone contact information, and a copy of your original tax invoice.
  • Page 66 Regency GF950L Gas Fireplace...
  • Page 67 WARRANTY warranty Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 69 NOTES notes Regency GF950L Gas Fireplace...
  • Page 70 notes NOTES Regency GF950L Gas Fireplace...
  • Page 71 Regency GF950L Gas Fireplace...
  • Page 72 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency and Greenfire are registered trademarks of FPI Fireplace Products International Ltd. © Copyright 2018, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Greenfire gf950l seriesGf950l-lpGf950l-ulpg

Table of Contents