GAS POWER FLUE INSTALLATION CLEARANCE REQUIREMENTS
Gas Power Flue Installation Clearance Requirements
INLINE POWER FLUE TERMINATIONS
Inline Power Flue Terminations
Confined spaces (chase, closet, attic, behind a wall):
• 76mm clearance is required on top of the power flue in a horizontal configuration (Diagram 2).
• 51mm clearance is required on the sides and bottom in a horizontal configuration (Diagram 2).
• 305mm clearance is required from the ends of the power flue in a horizontal configuration (Diagram 1).
• 51mm clearance is required on sides in a vertical configuration (Diagram 2).
• 305mm clearance is required on ends in a vertical configuration (Diagram 1).
• A framed access hole with dimensions of 305mm x 406mm is required to access the access panel if the inline power flue is placed behind a
wall (Diagram 3).
• The access hole can be covered with an open-air louver cover which allows 50% open air.
• The power flue must be installed where it can be easily accessed for servicing. An access hole as noted below, or an attic space, would be
suitable.
305mm
406mm
Diagram 3