installation

FLUE RESTRICTOR POSITION

FLUE RESTRICTOR SETTING
22
Flue restriction is required for certain flueing installations, see the diagrams
in the "Flueing
Arrangements" section to determine if they are required for your installation.
The Flue Restrictor plate is located on the inside top of the firebox.
Set 3 - 18mm open
To set the flue restriction as indicated in the flueing arrangements diagrams,
refer to the following instructions;
1. Remove the glass door and inner panels - see instructions in this manual.
2. Remove 6 screws (3 front - 3 back) to remove heat baffle to access restrictor
3. Remove the screws that hold the flue restrictor in place.
Set 2 - 25mm open
Set 1 - 50mm open
4. Adjust the flue restrictor plate to the required flue restrictor position as per
5. Once the flue restrictor plate is in the required position, secure with screws.
Set 0 - 75mm Open
(Factory Setting)
plate.
the diagrams shown below.
Heat Baffle
Regency GF950L-2 Gas Fireplace