Horizontal Terminations - Inline Power Flue 102Mm X 168Mm Flex Flue - Regency Fireplace Products Greenfire GF950L Owners & Installation Manual

Hide thumbs Also See for Greenfire GF950L:
Table of Contents

Advertisement

installation
HORIZONTAL TERMINATIONS - INLINE POWER FLUE
102MM X 168MM FLEX FLUE
These flueing systems, in combination with the GF950L-2 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system. The location
of the termination cap must conform to the requirements in the Flue Terminal Locations diagram in "Exterior Flue Termination Locations" section.
Regency
Direct Vent (Flex) System Termination Kits include all the parts needed to install the GF950L-2 using a flexible flue.
®
Notes:
1. Only Flex pipe purchased from Regency
used for Flex installations
2. Horizontal flue must be supported every 0.9 meter.
3. Regency
®
Direct Vent System (Flex) is only approved
for horizontal terminations.
4. Flex system can only be used up to a maximum
flue length of up to 12m using up to 2 x 6m flex kits
(Part # 946-756). If longer runs are required, rigid
pipe must be used.
5. Must use adaptor pipe (946-219/P) to connect inner
flex pipe as shown.
IMPORTANT:The inline power flue must be installed
within the confines of the home/structure and must
be accessible for future servicing. An access hole
as noted in this manual or an attic space would be
suitable.
Maximum total flue length = 18m maximum of six-90
elbows permitted.
One 90
elbow = two 45
elbows
0
0
Maximum total negative flue length = 2,1m
Note: Maximum length of 18m is based on overall
length of combined chimney components.
Do not run positive flueing after a negative run.
Inline power flue location restrictions:
Minimum 1.2 m from the unit
Minimum 0.3 m prior to an elbow.
Minimum 0.3 m following an elbow.
Minimum 0.3 m prior to a termination cap.
Minimum 1.8 m rise from top of unit if there
is a negative run.
Power Flue Kit (Part 946-765)
2 Max.
946-756
1
1
946-765
1
946-219/P
1
946-206
1
946-523/P
1
946-763
1
946-506/P
1
911-339
40
®
may be
168mm
Dia. Flue Pipe
0
6m Flex Kit
Sold separately
Power Flue Fan
Included w/Power Flue Kit
Power Flue Kit
Sold separately
Adaptor Pipe
Included w/Power Flue Kit
Vinyl Siding Standoff
Sold separately
Astro Cap Termination
Sold separately
Wall Thimble
Sold separately
Flue Guard
Sold separately
PV Wiring Harness
Included w/Power Flue Kit
Maximum 2 - 6.10m
long liners
Adaptor Pipe
(Part # 946-219/P)
Power Flue Terminal
(Part # 946-765)
102mm
Dia. Flue Pipe
Vent Guard - if required
(Part #946-506/P)
AstroCap
(TM)
Termination Cap
(Part #946-523/P)
Wall Thimble
Regency GF950L-2 Gas Fireplace