Rigid Pipe Venting Systems-Basic Horizontal & Vertical Terminations - Regency Fireplace Products Bellavista B41XTE-NG11 Owners & Installation Manual

Table of Contents

Advertisement

Rigid Pipe Venting Systems-Basic Horizontal & Vertical Terminations
Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decora-
tive black, as well as galvanized finish.
The minimum components required for a basic Horizontal Termination are:
1
AstroCap XL Termination Cap
1
90
Elbow
o
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of rigid pipe to suit wall thickness
The minimum components required for a basic
Vertical Termination are:
1
Vertical Termination Cap
1
Rigid Pipe Adaptor
1
Lengths of pipe to adequately
penetrate roof
1
Ceiling Firestop
1
Flashing
1
Storm Collar
Wall thickness
is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl, furring
strips may be used, instead of a vinyl siding
standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
WARNING:
Do not combine venting components from
different venting systems.
Exception: However, use of the the AstroCap
XL
is acceptable with all systems.
TM
This product has been evaluated by Intertek
when using a rigid pipe adaptor and use of
any of the specific chimney systems listed in
this manual. Use of these systems with the
rigid pipe adaptor is deemed acceptable and
does not affect the Intertek WHI listing of these
components.
The Regency AstroCap
and Regency Riser Vent terminal are certified for installations using Regency venting systems as well as any specific chimney
TM
systems listed in this manual. AstroCap
Vertical Terminal
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
Pipe
Length
Alternate
Horizontal Termination
Caps
Alternate Snorkel
Termination Cap
TM
is a proprietary trademark of Regency Fireplace Products.
Vinyl Siding
Standoff (Optional)
Horizontal Terminations)
Pipe Length
o
90 Elbow
Rigid Pipe
Adaptor (770-994)
Simpson Dura-Vent, 3 screws must be
Regency Bellavista
installation
Vent Guard - if required*
(Part #946-506/P)
AstroCap XL
Termination Cap
(Part #946-623/P)
Wall Thimble
(Mandatory in all
When using Rigid Vent other than
used to secure rigid pipe to adaptor.
B41XTE -11 Gas Fireplace
®
|
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bellavista b41xteBellavista b41xte-lp11

Table of Contents