END OF LINE POWER FLUE MAINTENANCE
EXTERNAL POWER FLUE ACCESS
1. Remove 4 screws located around inner trim (Diagram 1).
Diagram 1
2. Loosen 4 screws (Diagram 2) and slide shield up and out. Once access has
been made into power flue housing, you can remove the pressure switch
and fan motor.
Diagram 2
3. Remove the pressure switch by disconnecting red and green wires from
pressure switch (Diagram 3) Disconnect Hose from underside of pressure
switch (Diagram 4)
Diagram 3
4. Loosen (1) one Phillips head screw securing the pressure switch to the power
flue housing (Diagram 5) once the pressure switch is free from the Housing
unit, it is possible to replace the pressure switch by removing (1) one Phillips
head screw holding the pressure switch to mounting bracket (Diagram 6).
Diagram 5
Regency GF950L-2 Gas Fireplace
Diagram 4
Diagram 6
Replacing the power flue motor:
1. Turn off power supply.
2. Loosen 6 x 1/4" hex screws slightly.
3. Turn power flue motor counter clockwise and lift out (Diagram 7).
Diagram 7
4. Disconnect power to the motor by disconnecting black and black wire and white
and black wire (Diagram 8). The power flue motor is now free from the unit.
5. Loosen 4 screws and slide shield up and out (Diagram 2). Once access to
the power flue housing is achieved, you can remove the pressure switch
and fan motor.
6. Remove the pressure switch by disconnecting the red and green wires from
the pressure switch (Diagram 3)
7. Disconnect the hose from the underside of the pressure switch (Diagram 4).
Loosen one Phillips head screw holding the pressure switch to the power
flue housing (Diagram 5). Once the pressure switch is free from the hous-
ing it is possible to replace the pressure switch by removing one Phillips
head screw holding the pressure switch to mounting bracket. (Diagram 6)
8. To replace the power flue motor, first turn off the power supply, then slightly
loosen 6 x 6.35mm hex screws. Turn the power flue motor counter clockwise
and pull it out (Diagram 7).
9. Disconnect the power to the motor by disconnecting the black and black
from the terminal block. The power flue motor is now free.