UNIT INSTALLATION
WITH HORIZONTAL TERMINATION-
END OF LINE POWER FLUE
102MM X 168MM FLEX FLUEING
Minimum Flue Clearances
to Combustibles
* Clearances noted below must be maintained; except
when passing through a wall, ceiling or at the termination
where the use of a firestop or wall thimble reduces
clearance to 38mm.
Horizontal Top*
76mm*
Horizontal Side
51mm
Horizontal Bottom
51mm
Vertical Flue
51mm
Below are the recommended framing dimensions
(inside measurements) for the 102mm x 168mm
rigid flue terminations - for use with a firestop or
wall thimble.
Recommended Framed Opening Size
Flue Size
Framing Size
102mm x 168mm
254mm x 254mm
1. Locate the unit in the framing, rough in the gas
(preferably on the right side of the unit). Locate
the centerline of the termination and mark wall
accordingly. Cut an square hole in the wall - see
chart (inside dimension).
2. Level the fireplace and fasten it to the framing
using nails or screws through the nailing strips.
3. Assemble the flue assembly by applying Mill
Pac to the inner flue collar of the termination
and slipping the inner flex liner over it at least
35mm. Fasten with the 3 screws (drilling pilot
holes will make this easier). Apply Mill-Pac to
the outer flex pipe and slip it over the outer flue
collar of the flue terminal at least 35mm and
fasten with the 3 screws.
Regency GF950L-2 Gas Fireplace
NOTE: Horizontal sections must be supported
at intervals not exceeding 3 feet (0.9
meter). (Flame picture and performance
will be affected by sags in the liner).
4. Slip the assembled liner and termination as-
sembly through the thimble making sure the
termination cap faces up (there are markings
on the cap indicating which way is up). This will
position the termination cap with proper down
slope for draining water. Fasten the cap to the
outer wall with the 4 supplied screws.
5. Pull the centre inner and outer flex liner out
enough to slip over the flue collars of the fire-
place. (You may wish to cut the liner shorter
to make it more workable.) Do not bend liner
more than 90°. The liners must slip over the
collars a minimum of 35mm.
6. Apply Mill Pac over the fireplace inner flue
collar and slip the inner flex liner down over it
and attach with 3 supplied screws.
7. Do the same with the outer flue collar and outer
flex liner.
8. Apply a bead of silicone between the thimble
and termination and around the outer edge of
the terminal at the wall in order to keep the
water out.
IMPORTANT: Do not locate termination
hood where excessive snow or ice buildup
may occur. Be sure to check flue termination
area after snow falls, and clear to prevent
accidental blockage of flueing system. When
using snow blowers, make sure snow is not
directed towards flue termination area.
installation
61