Vertical Inline Power Vent Terminations - Rigid Pipe - Regency Fireplace Products City Series Owners & Installation Manual

Direct vent gas power vent fireplace, single sided
Hide thumbs Also See for City Series:
Table of Contents

Advertisement

CV72EPV/CB72EPVCB40EPV/CC40EPV/CV40EPV/CB60EPV/CV60EPV
installation
Vertical Inline Power Vent Terminations
Rigid Pipe
Vertical Inline Power Vent Terminations
Rigid Pipe
The minimum components required when using inline power
vent are:
1
High Wind Cap
1
Rigid Pipe Adaptor (510-994)
1
Ceiling Firestop
1
Flashing
1
Storm Collar
1
Lengths of pipe to suit wall thickness & vent run
(see chart)
1
Inline Power Vent Kit
Galvanized pipe is desirable above the roofline due to its higher
corrosion resistance. Continue to add pipe sections through the
flashing until the height of the vent cap meets the minimum height
requirements specified in table below or local codes. Note that for
steep roof pitches, the vertical height must be increased. A poor
draft, or down drafting can result from high wind conditions near
big trees or adjoining roof lines, in these cases, increasing the
vent height may solve the problem.
Roof Pitch
Minimum Vent Height
flat to 7/12
2
over 7/12 to 8/12
2
over 8/12 to 9/12
2
over 9/12 to 10/12
2.5
over 10/12 to 11/12
3.25
over 11/12 to 12/12
4
over 12/12 to 14/12
5
over 14/12 to 16/12
6
over 16/12 to 18/12
7
over 18/12 to 20/12
7.5
over 20/12 to 21/12
8
WARNING:
Do not combine venting components from different venting systems.
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with
Duravent Direct-Vent, Selkirk Direct-Temp, Ameri Vent Direct Venting, ICC Excel Direct, Olympia
Ventis DV, and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is
deemed acceptable and does not affect the Intertek WHI listing of components.
| CV40EPV City Series
42
920-210c
Inline Power Vent Vertical or Hortizontal Installation Instructions
Feet
Meters
0.61
0.61
0.61
0.76
0.99
1.22
1.52
1.83
2.13
2.29
2.44
High Wind Cap
Ceiling Firestop
Lengths of Pipe
Inline Power Vent Kit
Lengths of Pipe
CV72EPV shown
3
Storm Collar
Flashing
Slip Section
Rigid Pipe Adaptor
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must
be used to secure rigid pipe to
adaptor.
10.04.21