Vertical Flue Extension Kit; Ceiling Firestop/Firestop Spacer - Regency Fireplace Products Greenfire GF950L Owners & Installation Manual

Hide thumbs Also See for Greenfire GF950L:
Table of Contents

Advertisement

installation
VERTICAL FLUE EXTENSION KIT (PART #946-756)
VERTICAL FLUE EXTENSION KIT (PART # 946-756)
6.1 m Flex pipe Extension
(Used in conjunction with the 946-768 Vertical Flex kit and 948-367/P
flex to flex adaptor).
1. Stretch out both inner 102 mm and outer 168 mm pipe up to
a maximum of 6 m.
Note :The inner and outer pipes may be cut if only a short length is required.
2. Install spring spacers around 102 mm inner pipe as shown.
Slide outer flex pipe over and all the way down the 102 mm pipe.
3. Apply a bead of Mill Pac around the perimeter of the 102 mm inner
collar of the flex adapter and slip the 102 mm inner flex pipe from the
Vertical termination kit over the flex adapter ensuring that the inner flex
pipe overlaps the collar by at least 35 mm. Fasten with 3 screws.
4. Apply a bead of Mill Pac around the perimeter of the 168 mm outer collar
of the flue adapter and slip it over the 168 mm outer flex pipe from the
vertical termination kit ensuring that the outer flex pipe overlaps the collar
by at least 35 mm. Fasten with the 3 screws.
5. Repeat steps to secure the other end of the flex adapter using the flex kit.
6. See Vertical Vent installation instructions for installation of the complete
vent system.
Note: If an offset is necessary in the attic or floor joists it is important to
sup-port the vent pipe every 0.91 m to avoid excessive stress and sagging
of the vent pipe. Wall straps are provided (3 in total) for this
purpose.
All round/plumbers strapping may also be used if further supports are
required.

CEILING FIRESTOP/FIRESTOP SPACER

CEILING FIRESTOP / FIRESTOP SPACER (PART #946-757)
( PART # 946-757)
Used in conjunction with the 946-768 Vertical flex kit and 946-756 kit Vertical
flex extension kit/Horizontal power vent kit.
A ceiling firestop/firestop spacer must be installed when passing through
each floor or ceiling level. To install the ceiling firestop/firestop spacer in
a flat ceiling or floor joist cut a 260 mm square hole. Frame the hole as
show in Diagram 1 and install the ceiling firestop. Slide the top attic insula-
tion spacer onto the top of the attic insulation shield/firestop - See Diagram
1a. Secure with 4 screws/nails. If more than one is required, these can be
purchased separately.
Note: The ceiling firestop/firestop spacer may be cu t down to si z e if th is shield
is too high for the application.
919-698
CEILING FIRESTOP/FIRESTOP SPACER
( PART # 946-757)
919-696
34
Used in conjunction with the 946-755 Vertical flex kit and 946-756 kit Vertical
102 mm inner
pipe 6 m
168 mm
outer flex pipe
6 m
-1/4
60
Ceiling firestop
Diagram 1
Diagram 1a
1
1
10 spring spacers
flex adaptor
3 wall straps
Termination Cap
Storm Collar
Flashing
Firestop spacer to prevent
debris from falling into the ceiling
firestop
Roof support
Ceiling firestop
Enclosure
Ceiling firestop
Regency GF950L-2 Gas Fireplace
06.12.18