FLUEING ARRANGEMENT FOR VERTICAL TERMINATIONS (NON POWER FLUE)
Vertical Flueing with Two (2) 45
The shaded area in the diagram shows all allowable combinations
of straight vertical and offset to vertical terminations, using two
elbow, with Rigid Pipe Flueing Systems.
45
o
Flue must be supported at offsets.
Minimum distance between elbows is 305mm.
Maintain clearances to combustibles as listed in the
"Clearances" section in the manual.
Horizontal flue must be supported every 1M.
Refer to the "Flue Restrictor Position" section for
details on how to change the flue restrictor from the
factory setting of Set 0 or Set 3 if required.
Note: For ULPG Flue Restrictor - Set to "0" - 75mm
open.
Regency GF950L-2 Gas Fireplace
Elbows
o
Metres
NOTE: FOR ULPG
FLUE RESTRICTOR
SET TO "0" - 75mm OPEN
trictor Set #3
Res
18mm open