installation
845 S.I.T. VALVE
DESCRIPTION
1) On-Off Solenoid Valve EV1
2) On-Off Solenoid Valve EV2
3) Inlet Pressure Test Point
4) Outlet Pressure Test Point
5) Connection for Pressure Regulator/Combustion
Chamber Compensation
6) Pressure Regulator for Minimum and Maximum
Outlet Pressure
7) Gas Outlet Pressure Electric Modulator
8) Pilot Outlet
9) Main Gas Outlet

AERATION ADJUSTMENT

The burner aeration is factory set but may need adjusting due to either the
local gas supply or altitude. Open the air shutter for a blue flame or close for
a more yellow flame.
Minimum Air Shutter Opening for Natural Flue:
NG
9.5 mm
Propane 13 mm
ULPG
Full Open
Note: Any damage due to carboning resulting from improperly setting
the aeration controls is NOT covered under warranty.
Minimum Air Shutter Opening for Power Flue:
NG
4.4 mm
Propane 11 mm
ULPG
13 mm
Note: Ensure aeration is set to correct configuration.
66
Regency GF950L-2 Gas Fireplace