End Of Line Power Flue - Regency Fireplace Products Greenfire GF950L Owners & Installation Manual

Hide thumbs Also See for Greenfire GF950L:
Table of Contents

Advertisement

installation
GAS POWER FLUE INSTALLATION - END OF LINE POWER FLUE
WARNING
ELECTRICAL CONNECTIONS SHOULD ONLY BE
CARRIED OUT BY A QUALIFIED AND LICENSED ELEC-
TRICIAN
1. Frame an opening to the outside of the building at 343mm W x
343mm H to accommodate the Power Flue.
13-1/2"
343mm
(343mm)
Determine
the correct
height
2. Run the flueing and power flue wire harness from the unit to the framed
opening.
3. Determine the building finishing material thickness.
4. Depending on the building material thickness, install the frame onto the Power
Flue mount using 4 screws. Mounting holes start at 51mm from the front of
the Power Flue unit cover and can be adjusted back in 19mm increments.
NOTE: Exterior finishes such as thin vinyl siding may warp if closer than
51mm from the flue. For interior installations on vinyl siding, a 51mm
frame/buffer zone must be created between the finishing and the flue.
Adjustable Power Flue Frame
64
13-1/2"
343mm
(343mm)
Determine finishing
material thickness
Determine protrusion
of faceplate
Set frame depth
(starting @ 2" of
faceplate protrusion)
5. Install Power Flue unit into framed opening using 4 screws as shown below.
6. Seal the edges of the Power Flue unit to the framing (there are two seams).
Silicone edge of inner trim
against siding of structure,
wipe any excess silicone off
trim.
Fan discharge
opening
Seal behind flange with silicone--
screw against Plywood siding. Wipe
any excess silicone off outer flange
after flange is screwed down.
Regency GF950L-2 Gas Fireplace

Advertisement

Table of Contents
loading