INSTALLING A TV / ARTWORK FLUSH WITH THE UNIT

Note: All wiring should stay free and clear of the flue system to avoid damage due to heat, if located directly in front of the flue system.
Ensure wiring is secured without any sag.
Heat deflector must overhang front of TV by 51mm.
Follow mantel clearance chart for install height and heat deflector depth.
A—Depth of TV & Mounting Bracket
127mm
153mm
178mm
203mm
229mm
A
C
B
13mm Air Gap
Note: The TV mounting bracket can not be secured directly to the appliance. It must be secured to framing. The TV depicted in the picture may need to be
higher depending on the style of TV mounting bracket used. The mounting bracket shown is a simple single strip TV secured to framing.
Regency GF950L-2 Gas Fireplace
B—Height From Base of Unit
879mm
901mm
920mm
942mm
961mm
51mm
L
C—Distance From Top of 13mm Air Gap
261mm
283mm
302mm
324mm
343mm