Selector
No.
Delay time from when
1
documents are set until the
|
ADF starts drawing them in
3
(Not used.)
Periodical correction intervals
of the reference voltage to be
4
applied to white level
|
compensation for document
6
scanning, during standby
(Not used.)
7
Standby position of the CIS unit
8
Line polarity reversal detector
Selectors 1 through 3: Delay time from when documents are set until the ADF starts drawing them in
These selectors determine how long the ADF will delay automatic drawing-in of documents (to the
scanning standby position) after you set them in the ADF, as well as determining whether or not the
ADF automatically draws in documents.
Selectors 4 through 6: Periodical correction intervals of the reference voltage applied to white level
These selectors set the correction intervals (in seconds) of the reference voltage to be applied to white
level compensation for document scanning during standby, as well as determining whether or not the
controller makes the reference voltage correction during standby. (Conventionally, the correction has
been made immediately before the start of actual scanning)
This function takes effect in copying. Making the correction during standby may shorten the
preparation time for copying.
NOTE: Do not access these selectors.
Selector 7:
Standby position of the CIS unit
This selector determines whether the standby position of the CIS unit should be the home position or
the location of the white reference film (attached to the inside of the scanner top cover). If the
location of the reference film is selected, the CIS unit will not return to the home position so as to
shorten the travel time, decreasing the preparation time for copying.
WSW45 (
Speeding up scanning-2)
Function
(Not used.)
compensation for document scanning, during standby (Not used.)
App. 4-49
Setting and Specifications
No. 1 2 3
0 0 0 : No automatic drawing-in
0 0 1 :
1 sec.
0 1 0 :
2 sec.
0 1 1 :
3 sec.
1 0 0 :
4 sec.
1 0 1 :
5 sec.
1 1 0 :
6 sec.
1 1 1 :
7 sec.
No. 4 5 6
0 0 0 : No correction of reference
voltage during standby
0 0 1 :
10 sec.
0 1 0 :
30 sec.
0 1 1 :
1 min.
1 0 0 :
3 min.
1 0 1 :
5 min.
1 1 0 :
10 min.
1 1 1 :
30 min.
0: CIS home position
0: Disable
1: Location of
the white reference
film
1: Enable
sec.: second(s), min: minute(s)