Selector
No.
1
First transmission speed choice for
|
fallback
4
5
Last transmission speed choice for
|
fallback
8
NOTE: WSW39 takes effect only when the V.34 mode is permitted (WSW19, selector 7) in models
supporting V.34 mode. For the transmission speed setting in other modes, refer to WSW19.
Selectors 1 through 8: First and last choices of transmission speed for fallback
These selectors are used to set the modem speed range. With the first transmission speed choice
specified by selectors 1 through 4, the machine attempts to establish the transmission link via the
modem. If the establishment fails, the machine automatically steps down to the next highest speed
and attempts to establish the transmission link again. The machine repeats this sequence while
stepping down the transmission speed to the last choice specified by selectors 5 through 8.
If the modem always falls back to a low transmission speed (e.g., 24,000 bps), set the first
transmission speed choice to the lower one (e.g., modify it from 31,200 bps to 26,400 bps) in order
to deactivate the high-speed modem function and reduce the training time for shorter transmission
time.
WSW39 will be limited by selectors 3 through 8 on WSW40.
WSW39
(V.34 transmission speed) (Not used.)
Function
App. 4-43
Setting and Specifications
No. 1
2
3
4
No. 5
6
7
8
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
:
2,400 bps
:
4,800 bps
:
7,200 bps
:
9,600 bps
: 12,000 bps
: 14,400 bps
: 16,800 bps
: 19,200 bps
: 21,600 bps
: 24,000 bps
: 26,400 bps
: 28,800 bps
: 31,200 bps
: 33,600 bps
: 33,600 bps
: 33,600 bps
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfc685cwMfc680cnMfc465cnMfc265cMfc885cwMfc235c

Table of Contents