9.2.2.3

Measuring of RSSI (Received Signal Strength Indicator) (Function code 195)

Function
This function is used to measure the RSSI (received signal strength indicator) of outside radio
frequency interference (RFI) with the frequency band in a channel selected in an environment where
the cordless handset is used.
Select a channel (001ch through 089ch) and measure the RSSI using the procedure below. Lower
measured value means less radio frequency interference and better communications state.
If noise is heard with the cordless handset due to radio frequency interference, changing the locations
of the machine and the cordless handset may avoid the noise.
Operating Procedure
(1) On the cordless handset, press the Menu/OK, *, #, 1, 9, 5, and # keys in this order in the
standby state.
The following appears on the handset's LCD.
RF TEST MODE
RSSI
CH = 040
(2) To change the channel, enter a 3-digit channel number from 001 through 089 using the
numerical keys or the arrow keys ( or ) on the cordless handset.
(3) Press the Menu/OK key on the cordless handset to start measuring the RSSI.
RSSI
CH = 089
Where, "H" or "L" at the end of the first line means high or low gain modulation, respectively.
Pressing the
Note: The higher the measured value, the higher the radio frequency interference.
(4) To measure the RSSI for other channels, repeat steps (2) and (3) above.
(5) To returns to the standby state, press the Off key.
****H
or
key switches to high or low gain modulation, respectively.