Brother MFC260C Service Manual page 390

Facsimile equipment
Hide thumbs Also See for MFC260C:
Table of Contents

Advertisement

Selector
No.
1
Not used.
Time length from transmission
2
of the last dial digit to CML
ON
Time length from CML ON to
3
CNG transmission
Time length from CML ON to
CED transmission (except for
4
facsimile-to-telephone
switching)
5
No. of training retries
6
7
Encoding system
(Compression)
8
Selector 2:
Time length from transmission of the last dial digit to CML ON
This selector sets the time length from when the machine transmits the last dial digit until the CML
relay comes on.
Selector 3:
Time length from CML ON to CNG transmission
This selector sets the time length until the machine transmits a CNG after it turns on the CML relay.
Selector 4:
Time length from CML ON to CED transmission
This selector sets the time length until the machine transmits a CED after it turns on the CML relay.
This setting does not apply to switching between facsimile and telephone.
Selectors 5 and 6: No. of training retries
These selectors set the number of training retries to be repeated before automatic fallback.
Selectors 7 and 8: Encoding system (Compression)
This selector determines whether or not to allow the use of the MR/MMR coding system.
WSW10
(Protocol definition 2)
Function
MR
MMR
App. 4-14
Setting and Specifications
0: 100 ms
0: 2 sec.
0: 0.5 sec.
No. 5
6
0
0
:
1 time
0
1
:
2 times
1
0
:
3 times
1
1
:
4 times
0: Allowed
0: Allowed
1: 50 ms
1: 4 sec.
1: 2 sec.
1: Not allowed
1: Not allowed
sec.: second(s), ms: millisecond(s)
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfc685cwMfc680cnMfc465cnMfc265cMfc885cwMfc235c

Table of Contents