System; Switch On Input Delay - Eaton easy800 Manual

Control relay
Table of Contents

Advertisement

8 800 Settings

8.2 System

8.2 System

8.2.1 Switch on input delay

DEBOUNCE
åÆ
P PUSHBUTTONS
RUN MODE
CARD MODE
æ
302
Control Relay easy800 11/11 MN04902001Z-EN www.eaton.com
The easy800 device is factory set to evaluate input signals with an input
delay, the so-called DEBOUNCE function. This ensures that any contact
bouncing of switches and pushbuttons is masked out.
However, for many applications, it is necessary to evaluate very short input
signals. In this case, the debounce function can be switched off.
The input delay is set in the System menu.
▶ Press DEL and ALT to call up the System menu.
▶ Move to the menu SYSTEM and then to the DEBOUNCE menu.
If the easy800 device is protected with an STD PASSWORD,
you must remove password protection before you can call the
system menu.
Activating DEBOUNCE
▶ To activate DEBOUNCE, choose DEBOUNCE and press OK.
The debounce is activated and the display changes to DEBOUNCE
▶ Press ESC to return to the previous menu.
Deactivating DEBOUNCE
If the menu displays DEBOUNCE
debounce function is already activated.
▶ To deactivate DEBOUNCE, choose DEBOUNCE
Debounce mode will be deactivated and the display will show DEBOUNCE
without a tick.
How easy800 input signals are processed internally,
→ Section "Input delay (debounce)", Page 321.
å
(with a tick), this means that the
å
and press OK.
å
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Easy800-swd

Table of Contents