Function Group "System Parameters" (0C); Function "Tag No." (0C0); Function "Profile Version" (0C1), Profibus Pa Only; Function "Protocol+Sw-No." (0C2) - Pepperl+Fuchs Pulscon LTC Description Of Instrument Functions

Guided level radar with hart/4 ma ... 20 ma and profibus pa
Table of Contents

Advertisement

Pulscon LTC

Function group "system parameters" (0C)

12
+
E
12.1
+
E
You can define the tag number with this function.
User input:
16 alphanumeric characters for HART instruments
(8 using the HART universal command)
32 alphanumeric characteristics for PROFIBUS PA instruments
12.2
+
E
The PROFIBUS PA profile version is shown using this function (Profile 3.0).
Caution!
"
This function is available for PROFIBUS PA devices only!
12.3
+
E
This function shows the protocol and the hardware and software version: Vxx.yy.zz.prot.
Display:
xx: hw-version
yy: sw-version
zz: sw-revision
prot: protocoll type (e. g. HART)
12.4
+
E
This function displays the instrument serial number.
Function group "system parameters" (0C)

Function "tag no." (0C0)

Function "profile version" (0C1), PROFIBUS PA only

Function "protocol+sw-no." (0C2)

Function "serial no." (0C4)