Function "Upper Block. Dist" (059) - Pepperl+Fuchs Pulscon LTC Description Of Instrument Functions

Guided level radar with hart/4 ma ... 20 ma and profibus pa
Table of Contents

Advertisement

Pulscon LTC
Function group "extended calibr." (05)
7.10
+
E
For rod and rope probes with lengths of up to 8 m, the upper blocking distance is preset
to 0.2 m on delivery. For rope probes with lengths of more than 8 m, the upper blocking
distance is preset to 2.5 % of the probe lengths.
For media DC > 7, the upper blocking distance for rod and rope probes can be reduced
to 0.1 m, if the probe is mounted flush with the wall or in a nozzle of maximum 50 mm.
Blocking distance and measuring range
At the lower end of the probe there is no blocking distance but a transition region with
reduced accuracy, see section "Maximum measured error".
Rope probe
6 mm rod probe
16 mm rod probe
Coax probe
1.
Larger measurement range available on request.
2.
The indicated blocking distances are preset. At media with DC > 7, the upper blocking distance UB can
be reduced to 0.1 mm for rod and rope probes. The upper blocking distance UB can be entered manually.
Note!
!
Within the upper and lower blocking distance, a reliable measurement can not be
guaranteed.
For stilling well applications
The upper blocking distance (UB) is preset to 100 mm when the "bypass/pipe"
parameter has been selected in the "tank properties" (002) function.
Maximum measured error
Typical statements for reference conditions:
DIN EN 61298-2, percentage of the span.
Output:
sum of non-linearity, non-
repeatability and hysteresis
Offset/zero
If the reference conditions are not met, the offset/zero arising from the mounting
situation may be up to ± 12 mm. This additional offset/zero can be compensated for by
entering a correction (function "offset" (057)) during commissioning.

Function "upper block. dist" (059)

LTC
LN [m]
min
1
0.3
0.3
0.3
digital
measuring range:
- up to 10 m: ± 3 mm
- > 10 m: ± 0.03 %
for PA coated rope
measuring range:
- up to 5 m: ± 5 mm
- > 5 m: ± 0.1 %
± 4 mm
UB [m]
max
min
1)
2)
35
0.2
2)
2
0.2
2)
4
0.2
4
0
analogue
± 0.06 %
± 0.03 %
43