Function "Echo Quality" (056); Function "Offset" (057); Function "Output Damping" (058) - Pepperl+Fuchs Pulscon LTC Description Of Instrument Functions

Guided level radar with hart/4 ma ... 20 ma and profibus pa
Table of Contents

Advertisement

Pulscon LTC
Function group "extended calibr." (05)
+
E
+
E
+
E
42
7.7

Function "echo quality" (056)

20 mA
100 %
4 mA
0 %
The echo quality is the benchmark for measurement reliability. It describes the amount
of reflected energy and depends primarily on the following conditions:
Dielectric constant of the medium
probe type
Distance between sensor and product
Low values increase the probability that the echo is lost through a change in
measurement conditions, e. g. angels of repose or large measuring distance.
7.8

Function "offset" (057)

This function corrects the measured level by a constant value. The entered value is
added to the measured level.
7.9

Function "output damping" (058)

Influences the time an output requires to react to a sudden level jump (63 % of steady
state). A high value attenuates, for example, the influences of rapid changes on the
measured variable.
User input:
0 s ... 255 s
The default value depends on the selected application parameter
"process cond." (004).