7. LW3 Programmers' Reference
7.4. System Commands
7.4.1. Query the Product Name
The name of the product is a read-only parameter and cannot be modified.
Command and Response
ç GET·/.ProductName
pr·/.ProductName=<product_name>
æ
Example
ç GET /.ProductName
æ pr /.ProductName=RAP-B511-EU-K
7.4.2. Set the Device Label
This property can be changed to a custom text. The default format of the device label is the following:
LW_<product_name>_<serial_no>
ATTENTION!
The device label can be changed to a custom text in the
writable parameter is not the same as the ProductName parameter.
Command and Response
SET·/MANAGEMENT/LABEL.DeviceLabel=<custom_name>
ç
pw·/MANAGEMENT/LABEL.DeviceLabel=<custom_name>
æ
The Device Label can be 31 character length and ASCII characters are allowed. Longer names are truncated.
Example
ç SET /MANAGEMENT/LABEL.DeviceLabel=RAP-B511
æ pw /MANAGEMENT/LABEL.DeviceLabel=RAP-B511
7.4.3. Query the Serial Number
Command and Response
ç GET·/.SerialNumber
pr·/.SerialNumber=<serial_nr>
æ
Example
ç GET /.SerialNumber
æ pr /.SerialNumber=00009865
RAP-B511 series – User's Manual
Status
tab of the LDC software. This
Applied firmware package: v1.1.0b3b3 | LDC software: v2.5.1b5
7.4.4. Query the Firmware Version
Command and Response
ç GET·/SYS/MB.FirmwareVersion
pr·/SYS/MB.FirmwareVersion=<firmware_version>
æ
Example
ç GET /SYS/MB.FirmwareVersion
æ pr /SYS/MB.FirmwareVersion= v1.0.1b2
7.4.5. Resetting the Device
The device can be restarted – the current connections (LAN, RS-232 or USB) will be terminated.
Command and Response
ç CALL·/SYS:reset()
æ mO·/SYS:reset=
Example
ç CALL /SYS:reset()
æ mO /SYS:reset=
7.4.6. Restore the Factory Default Settings
Command and Response
ç CALL·/SYS:factoryDefaults()
æ mO·/SYS:factoryDefaults=
Example
ç CALL /SYS:factoryDefaults()
æ mO /SYS:factoryDefaults=
The device is restarted, current connections are terminated, and the default settings are restored. See the
complete list in the
Factory Default Settings
section.
69