Tcp Recognizer; Ir Recognizer; Gpio Input Level Change - Lightware RAP-B511-EU User Manual

Room automation panel
Table of Contents

Advertisement

 
4. Device Concept
Turn off the lamp
User interaction
Interaction state
Button press 2.
Incoming
RS-232 mes
sage
'the lamp is
turned off'
Do the following setting on the UI Config page:
Step 2. Select the Button1 and set the operation mode to Toggle. The first button press changes the interaction
state to true. It happens automatically.
Step 3. Choose the TRUE feedbacks tab and click on the RS-232 message recognized condition. Write the serial
message which is sent by the relay box about the lamp status in the entry field of the pop-up window
(e.g. 'the lamp is turned on'). Click Ok to save.
Step 4. Choose the FALSE feedbacks tab and click on the RS-232 message recognized condition. Write the serial
message which is sent by the relay box about the lamp status in the entry field of the pop-up window
(e.g. 'the lamp is turned off'). Click Ok to save.
The RS-232 recognizer settings has to be done with Lightware Device Controller Software (see details in the
RS-232 Message Recognizer
section) or with LW3 protocol commands (see more information in the
Message Recognizer
section).
For more information about the button configuration, see
4.3.3. TCP Recognizer
DIFFERENCE:

Below mentioned features are available from FW package v1.1.0b3.
The feature is almost the same as in case of the RS-232 but for the network interface: the incoming TCP
messages can be processed which may trigger actions. The combination of the TCP recognizer and the
Event Manager gives numerous opportunities for creating automatic room solutions.
TCP Recognizer Example
When the Projector switches off, the button light (2) of the RAP-B511 is turned off automatically.
Send
sage
RS-232 mes
'turn off the
FALSE
lamp'
UI Config Menu
section.
Applied firmware package: v1.1.0b3b3 | LDC software: v2.5.1b5
RAP-B511 series – User's Manual
When the power-off process is started in the projector, it will send a message over Ethernet. That message
will be recognized by the RAP-B511 and will be used as a Condition in Event Manager.
How to set up the RAP?
Step 1. Configure the recognizer for the communication by the LDC, (see the
Result
protocol commands (see the
client. (The Projector is saved as 'C1' in this example.)
The lamp is
Step 2. Create the following event in the Event manager:
turned off
E1. When the (PWR!001 "On") message is recognized from the C1 client, the Background light of
Button LED2 is set to Off state.
For more information about setting the events in LDC, see the
4.3.4. IR Recognizer
The RAP-B511 has a built-in IR eye with IR recognizer function. The incoming signal is stored in hash
(fingerprint), and it can trigger actions in Event Manager.
INFO:

All settings are available in the LDC software, more details can be found in the
IR Recognizer Example
IR signals are sent by the Remote controller, the projector is connected to the Ethernet port of the RAP-B511.
RS-232
Remote controller
The projector can be powered on via the RAP-B511 by using the remote controller with the following way:
Set an action in Event Manager: if the power button is pressed on the Remote controller, the RAP-B511
sends a control command ('Power on') to the projector via Ethernet. In this case you can control the
device via the RAP-B511 remotely. See the details about the Event Manager settings in the
Manager
4.3.5. GPIO Input Level Change
The GPIO (General Purpose Input/Output) port is a multifunctional input/output interface to control the
RAP-B511 or third-party devices and peripherals. You can establish connection between the controller/
controllable device and the RAP-B511 by the 4-pole Phoenix connector. Three pin's direction is configurable
independently based on needs of the application.
When the GPIO pin is used as an input, it is able to receive feedbacks from the other device by changing the
input level. The configuration is available in
TCP Message Recognizer
section). Define the desired device as a TCP
Event Manager
IR IN
Ethernet
ON
OFF
AUTO
RAP-B511
section.
UI Config Menu
and the
26
Ethernet
section) or by LW3
section.
Infra
section.
Projector
Event
Event
Manager.