Port Configuration; Protocol Setting; Baud Rate Setting; Databit Setting - Lightware RAP-B511-EU User Manual

Room automation panel
Table of Contents

Advertisement

 
7. LW3 Programmers' Reference
7.19. RS-232 Port Configuration
7.19.1. Protocol Setting
Command and Response
SET·/MEDIA/UART/P1.ControlProtocol=<cont_protocol>
ç
pw·/MEDIA/UART/P1.ControlProtocol=<cont_protocol>
æ
Parameters
Identifier
<cont_protocol>
Example
ç SET /MEDIA/UART/P1.ControlProtocol=1
æ pw /MEDIA/UART/P1.ControlProtocol=1
7.19.2. BAUD Rate Setting
Command and Response
SET·/MEDIA/UART/P1.Baudrate=<baud_rate>
ç
pw·/MEDIA/UART/P1.Baudrate=<baud_rate>
æ
Parameters
Identifier
<baud_rate>
Example
ç SET /MEDIA/UART/P1.Baudrate=2
æ pw /MEDIA/UART/P1.Baudrate=2
Parameter description
Parameter values
Selected protocol
0: LW2
1: LW3
Parameter description
Parameter values
Baud rate
0: 4800; 1: 7200; 2: 9600
3: 14400; 4: 19200; 5: 38400
6: 57600; 7: 115200
RAP-B511 series – User's Manual
7.19.3. Databit Setting
Command and Response
ç
æ
Parameters
Example
ç SET /MEDIA/UART/P1.DataBits=8
æ pw /MEDIA/UART/P1.DataBits=8
7.19.4. Stopbits Setting
Command and Response
ç
æ
Parameters
Example
ç SET /MEDIA/UART/P1.StopBits=0
æ pw /MEDIA/UART/P1.StopBits=0
7.19.5. Parity Setting
Command and Response
ç
æ
Parameters
Example
ç SET /MEDIA/UART/P1.Parity=0
æ pw /MEDIA/UART/P1.Parity=0
Applied firmware package: v1.1.0b3b3 | LDC software: v2.5.1b5
SET·/MEDIA/UART/P1.DataBits=<databit>
pw·/MEDIA/UART/P1.DataBits=<databit>
Identifier
Parameter description
<databit>
Databit
SET·/MEDIA/UART/P1.StopBits=<stopbit>
pw·/MEDIA/UART/P1.StopBits=<stopbit>
Identifier
Parameter description
<stopbit>
Stopbit
SET·/MEDIA/UART/P1.Parity=<parity>
pw·/MEDIA/UART/P1.Parity=<parity>
Identifier
Parameter description
<parity>
Parity
95
Parameter values
8: 8
9: 9
Parameter values
0: 1
1: 1,5
2: 2
Parameter values
0: no parity
1: odd
2: even

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rap-b511-kRap-b511-wRap-b511-sRap-b511-ukRap-b511-us

Table of Contents