Button Led Configuration; Enable The Button Led; Set The Default Intensity Of The Low Brightness - Lightware RAP-B511-EU User Manual

Room automation panel
Table of Contents

Advertisement

 
7. LW3 Programmers' Reference
Query the Actual Status
Command and Response
ç GET·/MANAGEMENT/UI/BUTTONS/<btn_ID>/BUTTON.ActualStatus
pr·/MANAGEMENT/UI/BUTTONS/<btn_ID>/BUTTON.ActualStatus=<btn_status>
æ
Parameters
Identifier
Parameter description
<btn_status>
Shows if the button is pressed or
not at the moment.
Example
ç GET /MANAGEMENT/UI/BUTTONS/BUTTON1/BUTTON.ActualStatus
æ pr /MANAGEMENT/UI/BUTTONS/BUTTON1/BUTTON.ActualStatus=up
Query the Clicked Status
Command and Response
ç GET·/MANAGEMENT/UI/BUTTONS/<btn_ID>/BUTTON.Clicked
pr·/MANAGEMENT/UI/BUTTONS/<btn_ID>/BUTTON.Clicked=<clicked_nr>
æ
Parameters
The
<clicked_nr>
parameter gives feedback about the number of the quick button presses (max. 1 sec
between the presses). After the clicking, the value restores to default (0) immediately. It can be set as a
condition in the Event Manager when the trigger should be e.g. a double click.
Example
ç GET /MANAGEMENT/UI/BUTTONS/BUTTON1/BUTTON.Clicked
æ pr /MANAGEMENT/UI/BUTTONS/BUTTON1/BUTTON.Clicked=0
Query the Longpress Status
Command and Response
ç GET·/MANAGEMENT/UI/BUTTONS/<btn_ID>/BUTTON.LongPress
pr·/MANAGEMENT/UI/BUTTONS/<btn_ID>/BUTTON.LongPress=<longpress_status>
æ
Parameters
Identifier
Parameter description
<longpress_status>
True, when the button has been
pressing more than 1 sec.
Example
ç GET /MANAGEMENT/UI/BUTTONS/BUTTON1/BUTTON.LongPress
æ pr /MANAGEMENT/UI/BUTTONS/BUTTON1/BUTTON.LongPress=false
Parameter values
up: The button is not pressed at the moment.
down: The button is pressed at the moment.
Parameter values
true: The button has been pressed more than 1sec.
false: The button has been pressed less than 1 sec.
Applied firmware package: v1.1.0b3b3 | LDC software: v2.5.1b5
RAP-B511 series – User's Manual
7.8. Button LED Configuration
General parameters
Identifier
<LED_ID>
LED identifier (LED1 is behind the BUTTON1)
7.8.1. Enable the Button LED
ATTENTION!

If the Button LED is not enabled, the following LED-related settings will not be displayed.
Command and Response
SET·/MANAGEMENT/UI/LEDS/<LED_ID>.Enabled=<LED_enable>
ç
pw·/MANAGEMENT/UI/LEDS/<LED_ID>.Enabled=<LED_enable>
æ
Parameters
<LED_enable>
true: The button LED is allowed to light.
false:The button LED is not allowed to light.
Example
ç SET /MANAGEMENT/UI/LEDS/LED11.Enabled=true
æ pw /MANAGEMENT/UI/LEDS/LED11.Enabled=true
7.8.2. Set the Default Intensity of the Low Brightness
Command and Response
SET·/MANAGEMENT/UI/LEDS.LowBright=<light_intensity>
ç
pw·/MANAGEMENT/UI/LEDS.LowBright=<light_intensity>
æ
Parameters
Identifier
<light_intensity>
The default intensity of the background light. 0-5:0 means no bright, 5 is the
Example
ç SET /MANAGEMENT/UI/LEDS.LowBright=1
æ pw /MANAGEMENT/UI/LEDS.LowBright=1
Parameter description
Parameter values
LED1-11
Parameter description
Parameter values
maximum brightness.
76