7. LW3 Programmers' Reference
7.10.3. Mute the Volume
Clicking on the jog dial changes the mute state (and toggles on and off the mute LED).
Command and Response
SET·/MANAGEMENT/UI/VOLUMECONTROL.Mute=<mute_state>
ç
pw·/MANAGEMENT/UI/VOLUMECONTROL.Mute=<mute_state>
æ
Parameters
<mute_state>
true or false
Example
ç SET /MANAGEMENT/UI/VOLUMECONTROL.Mute=false
æ pw /MANAGEMENT/UI/VOLUMECONTROL.Mute=false
7.10.4. Volume Setting in Mute State
This command allows setting the volume while the controlled device is in muted state.
Command and Response
SET·/MANAGEMENT/UI/VOLUMECONTROL.UnMuteOnVolumeChange=<unmute>
ç
pw·/MANAGEMENT/UI/VOLUMECONTROL.UnMuteOnVolumeChange=<unmute>
æ
Parameters
If the
<unmute>
parameter is true, the unmute command is sent, the LED is switched off and the volume
setting command is sent. If the
<unmute>
Example
ç SET /MANAGEMENT/UI/VOLUMECONTROL.UnMuteOnVolumeChange=false
æ pw /MANAGEMENT/UI/VOLUMECONTROL.UnMuteOnVolumeChange=false
7.10.5. Volume Control (Jog Dial) Status Indicators
These properties gives immediate feedback about the jog dial status. They are for using as a Condition in
the Event Manager.
Query the Rotating Direction of the Jog Dial
Command and Response
ç GET·/MANAGEMENT/UI/VOLUMECONTROL/ROTARY.RotaryPosition
pw·/MANAGEMENT/UI/VOLUMECONTROL/ROTARY.RotaryPosition=<direction>
æ
Parameters
If the
<direction>
parameter is 1, the jog dial is rotating clockwise. If the value is -1, the jog dial is rotating
counter clockwise. 0 value means the rotary does not turn (default value).
Example
ç GET /MANAGEMENT/UI/VOLUMECONTROL/ROTARY.RotaryPosition
æ pr /MANAGEMENT/UI/VOLUMECONTROL/ROTARY.RotaryPosition=-1
parameter is false, only the volume setting command is sent.
Applied firmware package: v1.1.0b3b3 | LDC software: v2.5.1b5
RAP-B511 series – User's Manual
Query the Actual Status of the Rotary
Command and Response
ç GET·/MANAGEMENT/UI/VOLUMECONTROL/ROTARY.ActualStatus
pr·/MANAGEMENT/UI/VOLUMECONTROL/ROTARY.ActualStatus=<rotary_status>
æ
Parameters
Identifier
Parameter description
<rotary_status>
Shows if the rotary button is
pressed or not at the moment.
Example
ç GET /MANAGEMENT/UI/VOLUMECONTROL/ROTARY.ActualStatus
æ pr /MANAGEMENT/UI/VOLUMECONTROL/ROTARY.ActualStatus=up
Query the Longpress Status
Command and Response
ç GET·/MANAGEMENT/UI/VOLUMECONTROL/ROTARY.LongPress
pr·/MANAGEMENT/UI/VOLUMECONTROL/ROTARY.LongPress=<longpress_status>
æ
Parameters
Identifier
Parameter description
<longpress_status>
True, when the rotary button
has been pressing more
than 1 sec.
Example
ç GET /MANAGEMENT/UI/VOLUMECONTROL/ROTARY.LongPress
æ pr /MANAGEMENT/UI/VOLUMECONTROL/ROTARY.LongPress=false
Query the Clicked Status
Command and Response
ç GET·/MANAGEMENT/UI/VOLUMECONTROL/ROTARY.Clicked
pr·/MANAGEMENT/UI/VOLUMECONTROL/ROTARY.Clicked=<clicked_nr>
æ
Parameters
<clicked_nr>
Gives feedback about the number of the quick button presses (max. 1 sec between the
presses).
Example
ç GET /MANAGEMENT/UI/VOLUMECONTROL/ROTARY.Clicked
æ pr /MANAGEMENT/UI/VOLUMECONTROL/ROTARY.Clicked=0
Parameter values
up: The rotary button is not pressed at the moment.
down: The rotary button is pressed at the moment.
Parameter values
true: The rotary button has been pressed more than 1 sec.
false: The rotary button has been pressed less than 1 sec.