5.6.4. Special Tools and Accessories
The Name of the Event
The name of a port can be changed by typing the new name and clicking the Set button. The following
characters are allowed when naming:
Letters (A-Z) and (a-z), numbers (0-9), special characters: hyphen ( - ), underscore ( _ ), and space ( ).
Enable or Disable an Event
The set Event can be enabled or disabled in the Event list, or directly in the Event editor window by setting
the tick mark beside the name.
Testing the Condition
When the desired Condition is arranged, the setting can be tested. The Event list and the Event editor contains
a small panel that shows if the set condition is detected and how many times. The Counter can be reset by
the button in Event editor. If the Condition is true, the detected mark turns green for two seconds and the
Counter is increased.
Testing the Action
The method is the same as testing the Condition, but in this case, the Action can be triggered manually by
pressing the Test button.

TIPS AND TRICKS:
The Test button is also placed on the Action panel in the Event list. Thus, you can
check the Actions without opening the Event editor.
Delay the Action
In most cases the Action is performed immediately after the Condition is detected. But sometimes a delay
is necessary between the Condition and the Action. Therefore, the new Event manager contains the Delay
panel which allows that feature with below settings:
No delay: when the Condition is detected, the Action is launched.
Simple delay: when the Condition is detected, the Action is launched after the set time interval.
Still true after: when the Condition is detected, the Action is launched after the set time interval only if
the Condition still exists.
Continuously true: when the Condition is detected, the Action is launched after the set time interval only
if the Condition has been existing continuously.
RAP-B511 series – User's Manual
TIPS AND TRICKS:

of a property but just the expression is displayed. The option is available in the Event list window or when
Link tool is used.
Variables
DIFFERENCE:

The variables and the tools (shown in the Control/Variables tab) can be used in the Event Manager.
Condition Wizard
The desired variable can be checked if its value is changed to a specific value.
Action Wizard
The value of a variable can be set/changed by the same methods as in the Control/Variables tab:
If the Use variables option is enabled, you can link a variable by the $ character. If you do so (e.g. $1), the
device will handle it as the V1 variable. You can send the value of the variable e.g. as a TCP message.
Condition Triggering

DIFFERENCE:
able from FW package v1.1.0b3.
This improvement works as if a condition
is detected. When a complex control
system is built, a Condition may trigger
numerous Actions. A typical example is
when a system is powered on and the 'ready-to-use' state has to be loaded. In this case, there could be many
actions which are based on the same condition. In order to reduce the number of the commands, you can
trigger one 'key' condition, which could start the whole process.
Applied firmware package: v1.1.0b3b3 | LDC software: v2.5.1b5
no delay
Condition = true
Perform the action
simple delay
Condition = true
Delay
still true after
Condition = true
Delay
continously
Condition = true
Perform the action
true
Delay
The available delay settings of an Event
Show advanced expressions option is a useful tool when you look for the path or value
This feature is available from FW package v1.1.0b3.
#variables
#new
Setting the exact value
Increasing the value with/without limits
Converting the value (e.g. interval change)
Scanning and storing, or reformatting a property/parameter
This feature is avail-
Perform the action
Condition = true Perform the action
Time
50