5. Software Control - Lightware Device Controller
ATTENTION!

If the login is enabled, the password will be asked when the
INFO:

The login password is erased and the login is disabled when restoring the factory default values.
Further functions
Download system log - saving the file of the device.
Load factory defaults - recalling factory defaults settings and values. All factory default settings are
listed in the
Factory Default Settings
Reboot - rebooting the
system. #factory
5.7.5. Time Settings
Real-Time settings can be managed from Time settings tab. For more details about the dependency of the
time properties, see the
Flowchart of the real-time clock configuration
Real time clock setting
In this section the current RTC (Real-time clock) time is displayed and can be modified manually. Click to Set
button to save the new setting.
Set time zone setting
Time zone can be selected from the drop-down menu.
Check Enable the daylight saving if it is needed, and set the start and end date. These setting will added
to the UTC (Universal Time Coordinated) and the NTP (Network Time Protocol) time.
INFO:

If the RTC time is set manually, these settings will be ignored.
Built-in Miniweb
section.
#log
#systemlog
#reboot #restart
process.
Applied firmware package: v1.1.0b3b3 | LDC software: v2.5.1b5
RAP-B511 series – User's Manual
is opened.
Set NTP (Network Time Protocol) settings
Enable NTP makes it possible to query time information from an NTP server. It means, that the
RAP-B511 is permitted to get time information from an NTP server. The device time synchronized
repeatedly and automatically. In this case, the NTP server address entry field is active, where the IP
address or URL of the NTP server can be typed manually. Click to set to save the address. The current
setting is also displayed.
Enable GET NTP from DHCP server means, when that DHCP server assigns an IP address to the RAP-B511,
its own IP address or URL can be queried, and this address may be saved as an NTP server. In this
case, the user does not have to give the IP address or URL manually.
Clicking on the Synchronize now button queries the time information from the NTP server. Time is
updated, when the device is restarted, powered off and on again and in certain time periods.
For more information about the time properties, the see the
chapter.
All settings are available with LW3 protocol commands, see the details in
programmers reference chapter.
5.7.6. Front Panel Settings
The following settings are available on the Front Panel tab:
Default low brightness and default high brightness intensity can be customized in 0-5 level scale where 0
means the no light, 5 means the maximum intensity.
The factory default value of the low brightness: 2
The factory default value of the high brightness: 5
You can disable the functionality of the front panel buttons and the rotary knob with marking the Lock
buttons option.
Clicking on Identify the device button results the front panel LEDs blink for 10 seconds which helps to
identify the device physically.
53
Real-Time Clock
in the Device Concept

Time Settings

section in LW3