7.9. Button Group Configuration
7.9.1. Set the Buttons into Groups
The button mode defines which button belongs a certain group. For more information about it, see
Button Operation Mode
section.
7.9.2. Query the Group Members
Command and Response
ç GET·/MANAGEMENT/UI/GROUP/<group_ID>.GroupMembers
pr·/MANAGEMENT/UI/GROUP/<group_ID>.GroupMembers=<member_list>
æ
Parameters
Identifier
Parameter description
<group_ID>
Group identifier
<member_list>
Shows which buttons belong to
the group. The members are listed
with their button ID numbers.
Example
ç GET /MANAGEMENT/UI/GROUP/G1.GroupMembers
æ pr /MANAGEMENT/UI/GROUP/G1.GroupMembers=1;2;3;
7.9.3. Set the Active Button
Command and Response
SET·/MANAGEMENT/UI/GROUP/<group_ID>.Active=<btn_nr>
ç
pw·/MANAGEMENT/UI/GROUP/<group_ID>.Active=<btn_nr>
æ
Parameters
Identifier
<group_ID>
Group identifier
<btn_nr>
Shows which button is the active member of the group.
It means, that the BUTTON<btn_nr>.State=true (and the
State property of the other members in the group are
false). For more information about the button states see
Set the Button Interaction State
Example
ç SET /MANAGEMENT/UI/GROUP/G1.Active=1
æ pw /MANAGEMENT/UI/GROUP/G1.Active=1
Parameter values
G1-5
1-11;1-11;...1-11;
Parameter description
Parameter values
G1-5
1-11
section.
Applied firmware package: v1.1.0b3b3 | LDC software: v2.5.1b5
RAP-B511 series – User's Manual
7.10. Volume Control Configuration
7.10.1. Control Lock of the Jog Dial
Set the
This property can disable the control function of the jog dial without locking the buttons.
Command and Response
SET·/MANAGEMENT/UI/VOLUMECONTROL.Enabled=<enabled>
ç
pw·/MANAGEMENT/UI/VOLUMECONTROL.Enabled=<enabled>
æ
Parameters
<enabled>
true: Jog dial control is enabled.
false: Operation of the jog dial is disabled. The mute LED and Rotary LEDs and are turned
down. When the rotary is turned, VOLUMECONTROL.Volume will not change, and the rotary
is pressed, the VOLUMECONTROL.Mute property will not toggle.
Example
ç SET /MANAGEMENT/UI/VOLUMECONTROL.Enabled=true
æ pw /MANAGEMENT/UI/VOLUMECONTROL.Enabled=true
ATTENTION!

When the rotary is disabled, the
Actual Status of the
7.10.2. Set the Volume
Rotating the jog dial changes the volume property value (and turns on and off the volume indicator LEDs)
between 0 and 16.
Command and Response
SET·/MANAGEMENT/UI/VOLUMECONTROL.Volume=<volume_value>
ç
pw·/MANAGEMENT/UI/VOLUMECONTROL.Volume=<volume_value>
æ
Parameters
<volume_value>
Example
ç SET /MANAGEMENT/UI/VOLUMECONTROL.Volume=5
æ pw /MANAGEMENT/UI/VOLUMECONTROL.Volume=5
Query the Rotating Direction of the Jog
Rotary,
Query the Longpress
Status,
Query the Clicked Status
0-16: Volume level can be set between 0 and 16.
78
Dial,
Query the
will change.