Setting Up Copper Tests
FED Control
FED States are displayed in the Current Test line as a numeral on the
right-hand side of the FED icon, for example
following states:
0 = Open
1 = T-R/A-B Shorted
2 = T-R-G/A-B-E Shorted
3 = Pass Through/Exchange Connect
4 = ID Tone
5 = Terminated (100
Note: A line termination of 150
6 = Crosstalk NEXT
7 = Transmit
8 = None
Note: For all FED States other than Pass Through/Exchange Connect, the
Dialer tab is disabled. If the dialer is already running before the test starts,
the dialer will be stopped on entry of the test with a message saying Dialer
cannot be used, hence dialer will be stopped. - similar to FaultMapper
test.
To select the parameter values:
1. Press the up/down arrow keys to highlight the desired parameter.
2. Press the left/right arrow keys to view and select the options.
OR
3. Press
up/down arrow keys to highlight the desired parameter.
4. Press
96
, 120
Ω
Ω
is not supported by the FED.
Ω
on a value to open a list box of options and press the
to confirm the value.
. Numerals match the
, 135
, 600
)
Ω
Ω
MAX-635G