Setting Up DSL/IP Tests
Setup
CRC/ES/SES Beep allows you to Enable/Disable an error-warning
beep while running a test. By selecting the error(s), you can
immediately identify lines with DSL errors. They are sampled
periodically and if any new errors are detected, the tester will generate
a short beep.
To access the parameter values:
1. Press the up/down arrow keys to highlight the desired parameter.
2. Press the left/right arrow keys to view and select the options.
OR
3. Press
4. Press
Identification
The Identification tab allows you to preset values to
identify each single and auto test result file when
saving them.
The parameters are as follows:
User Name/User ID allow you to enter up to 25
alphanumeric characters, in each field.
Contractor Name allows you to enter the name of
a contractor used to perform the tests.
Test From/To allows you to select from a list of
entries - up to 20 each, including user defined
values.
Test From/To List Setup buttons open separate list management
pages.
To select the parameter values:
1. Press the up/down arrow keys to highlight the desired parameter.
2. Press the left/right arrow keys to view and select the options.
362
on a value to open a list box of options.
to confirm the value.