Error Indications; Error Codes - Brother HL-L9300CDW Service Manual

Color laser printer
Hide thumbs Also See for HL-L9300CDW:
Table of Contents

Advertisement

3.

ERROR INDICATIONS

This machine includes a self-diagnosis function. If the machine does not work normally it
judges that an error has occurred, and indicates the corresponding error message on the LCD,
which in turn helps the service personnel to quickly find out the problem.
3.1

Error Codes

The shaded errors hardly occur under normal use. They may be caused by noise around the
installation site, variation in power supply voltage, or software failure.
Error
Description
Codes
0100
ASIC error or motor driver error
occurred.
0201
Synchronization signal from the
main motor cannot be detected.
Or the main motor speed is
unstable after a set period of
time.
0202
Synchronization signal from the
process motor cannot be
detected. Or the process motor
speed is unstable after a set
period of time.
0203
---
0204
---
0205
---
0206
---
0207
---
0208
---
0209
---
020F
The main motor other than the
official specifications is used.
0300
The Lock signal of the polygon
motor of the laser unit cannot be
detected.
0305
---
0401
BD sensor 1 damaged.
0402
BD sensor 4 damaged.
0405
---
Error
Refer
Codes
to:
2-41
0501
The center thermistor of the
fuser unit does not reach the
specified temperature within the
2-41
specified time.
0502
After the temperature of the
fuser unit rises to a certain level,
the temperature of the center
thermistor does not reach the
specified temperature within the
2-41
specified period of time in the
next step.
0503
The center thermistor of the
fuser unit detected a
temperature higher than the
specified value.
0504
After the center thermistor of the
fuser unit was normally heated,
it detected a temperature lower
than the specified value.
0505
The center thermistor of the
fuser unit detected a
temperature rise greater than
the specified value within a set
period of time.
2-42
0506
The center thermistor of the
fuser unit detected a
2-42
temperature fall greater than the
specified value within a set
period of time.
050A
The center thermistor or side
thermistor of the fuser unit
2-42
detected some temperature
2-42
error in the hardware.
2-10
Description
Confidential
Refer
to:
2-43
2-43
2-43
2-43
2-43
2-43
2-44

Advertisement

Table of Contents
loading

Table of Contents